3.3.4 Evolution DX2 Controller Wind Sensor Interfacing
The two wires from the wind sensor are connected to Input 4 (+) and Input 4 (-) on the
Sensor Terminal board via the Weather Station terminal block. Either wire may be
connected to either terminal connection.
3.3.5 Reading Wind Values at the DX2 Controller
Refer to Reading Rain Sensor Values at the Evolution DX2 Controller.
4.0 Maintenance
4.1 ET Tracker Maintenance
4.1.1 Adding Distilled Water
Distilled water may be added at any time by removing the top cup assembly of the ET
Tracker (release the spring retaining clips) and then pouring water down the tube. It is a
good practice to fill the reservoir in June. The reservoir supply should then last through
the summer months.
4.1.2 Cleaning the Ceramic Cup Assembly
After removal from the field in the fall, or periodically to ensure proper tracker operation,
the ceramic evaporating surface plate should be cleaned and reconditioned, as
described below.
CAUTION: Detergent should never be used to clean the ceramic plate.
4.1.3 Cleaning the Canvas Cover
Should the canvas cover become dirty, remove and wash with plain distilled water.
CAUTION: It is important to fit the canvas cover tightly to the ceramic cup so that
there is NO air space between the canvas cover and the evaporation
plate (See Figure 8: Assemblying the Top Cup).
4.1.4 Hard Ceramic Evaporation Plates
The ceramic evaporation plate design has a rounded (domed) top, which is made of a
hard ceramic material. All precautions regarding water compression may be
disregarded since the plate will not break under normal operating water pressure when
installing the rubber stopper.