Where to Place the Air Purifier:

The RainSoft

®

Airmaster DFS Air Cleaner is designed as a portable floor model.

Place the air purifier anywhere

in the room; being careful not to block air from “entering” the intake grill, or “exiting” the top grill cover.

Do not place the air purifier where drapes or other objects block airflow. For best performance, it is recommended

to place the air purifier at least two (2) feet from walls and other obstructions.

Air Cleaner Operation:

After removing the protective plastic from the unit – plug the unit into a standard 120 volt earth grounded AC

circuit. The control panel lights should be illuminated as follows:

Main Filter

- green light is

ON

Bio Monitor

- green light is

ON

The RainSoft

®

Airmaster DFS indicator light system is an all “green” system.

When the unit is operating properly, both indicator lights will be “green”.

Main Filter Light:

When the Main Filter is operating at full efficiency, the green light is always ON. When the light goes OFF, this is

your indication to “service” the Main Filter. The average life expectancy of the Main Filter is 12 to 16 months. See

Main Filter replacement instructions.

Bio Monitor Light:

Green light ON indicates that airborne micro-organisms are continuously being destroyed in the DFS Filtration

System. If the light goes OFF, micro-organism

destruction has been interrupted. Immediately turn off the unit and unplug it from the outlet. Call RainSoft

customer service at 1-800-860-7638 for servicing instructions.

Cleaning the Unit:

Before cleaning the unit, shut the air purifier OFF and unplug it from the outlet. Clean exterior surfaces only with a

soft cloth dampened with water. Do not use abrasive cleansers. Do not spray the unit with any liquid cleaner. Wipe

the intake grill weekly with a clean, dry non-static cloth.

Cleaning the Permanent Polyester Mesh Filter:

Clean the Permanent Polyester Mesh Filter by simply placing the unit on itʼs side and wipe clean.

Ordering Replacement Filters:

To order a replacement filter, contact your local RainSoft dealer. To locate a dealer visit www.rainsoft.com or call 1-

800-860-7638.

To Change Reversible Multi-Stage Filtration:

Carbon-Zeolite AND Dual Pre-Filtration Tray

DFS Main Filter Installation Instructions:

When the green Main Filter indicator light goes OFF, it is time to service the DFS

Main Filter. The average life expectancy of the Main Filter is 12 to 16 months.

CAUTION: Turn the air purifier off and unplug from power outlet.

1.

To access DFS Main Filter,

place fingertips under side

recesses of black cover, gently

pull outward and lift cover

to remove.

(Fig. A)

Separate

lid from the air purifier.

2.

To release Main Filter, move

both gray handles 90° toward

front of air purifier.

(Fig. B)

A

B

C

3.

To remove DFS Main Filter, lift

filter from the internal chamber.

(Fig. C) Before installing the

new Main Filter, make sure

the filter seal “O” ring is

seated properly in the “O”

ring channel.

1.

Turn the air purifier off and unplug from power outlet. To change/vacuum Carbon Filter, open back panel

(Fig. F)

remove

panel and set it down. Pull out carbon tray

(Fig. G)

and replace every 12 months. If you have a high level of particulates in

your home and/or animal hair you can easily vacuum the pre-filters between filter changes, which are located on the underside

of the carbon tray

(Fig. H)

. Simply vacuum the carbon tray pre-filter. Then turn the tray over and reinsert into filter draw. This

procedure can be repeated as necessary. However, it is highly recommended that this entire filter be replaced annually. Reattach

the back panel. Your unit is now ready for use.

F

G

H

D

4.

To load DFS Main Filter, align

hole in filter tab with brass pin.

Press filter down as shown.

(Fig. D).

To lock filter in place,

move both gray handles in 90°

toward the center of the filter

.

E

5.

To replace the lid, align the 2

vertical tabs, on the inside of

the lid, with the slots in the top

of the machine. Push down

gently and snap shut. Plug air

purifier into power outlet and

turn on.

NOTE:

The proper filter

must be used and

loaded correctly or air

purifier will not turn on.

CAUTION:

Do not force

handles, they should

move freely. If not,

realign the filter.

Main Filter Part #:

65132

Multi-Stage Filter Part #:

65131

Summary of Contents for Airmaster DFS

Page 1: ...06 09 Portable Room Air Cleaner o w n e r s m a n u a l...

Page 2: ...ier must be plugged into a 120 Volt AC earth grounded outlet Do not use this air purifier with a wall outlet adapter Do not operate this air purifier with an extension cord 1 Plug the unit DIRECTLY in...

Page 3: ...t requires service Bio Montior Light shows DFS germ killing zone is working at peak efficiency Convenient three speed control Low speed ULTRA quiet air flow mode GERM KILLING ZONE 98 100 of viruses 98...

Page 4: ...ays ON When the light goes OFF this is your indication to service the Main Filter The average life expectancy of the Main Filter is 12 to 16 months See Main Filter replacement instructions Bio Monitor...

Page 5: ...own Pull out carbon tray Fig G and replace every 12 months If you have a high level of particulates in your home and or animal hair you can easily vacuum the pre filters between filter changes which a...

Page 6: ...semble RainSoft Airmaster DFS offers a five year limited warranty on all consumer products 1 Retain proof of purchase and the original box and packaging materials 2 Mail Warranty Registration Card wit...

Page 7: ...y to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state You also have implied warranty rights In the event of a problem with warranty s...

Page 8: ...2080 E Lunt Ave Elk Grove Village IL 60007 Phone 1 800 860 7638 Fax 1 847 437 5539 To find your local RainSoft dealer visit www rainsoft com 2008 Rainsoft All rights reserved...

Reviews: