TO REMOVE THE DEW POINT and WIND CHILL FROM AUTO SELECT

      1.  Place the display in the setup mode.
      2.  Press 

HUMIDITY

.  The display will show             or            .  Use 

MIN

 or 

MAX

          

to change the setting.  If             is selected 

Dew Point

 and 

Wind Chill

 will not be 

          shown in the

 AUTO SELECT

 mode.

          
          

BAROMETER

1.

    The display is in the setup mode.

2. Press 

BAROMETER.

  The display will show             or            .   

“0” indicates that the  barometer is in inches of Mercury.  

3. Press 

MAX

 or 

MIN

 to change from Metric or English.

4. If you are finished with the setup mode, press AUTO SELECT.

  

RAINFALL

1.  The display is in the setup mode.
2. Press 

RAINFALL

.  The display will show            or            . 

  “0” indicates that the rainfall is in inches.  “1” indicates that the 

3. Press 

MAX 

or 

MIN

 to change from Metric or English.

4. If you are finished with the setup mode, press 

AUTO SELECT.

WIND SPEED

1.  The display is in the setup mode.
2.

              “O” indicates that the wind speed is in miles per hour.   

 that the wind speed is in knots.  “3” indicates that the wind speed is   

in meters per second.

3. Press 

MAX

 or 

MIN

 to change from mph or kph or knots or mps.

4. If you are finished with the setup mode, press 

AUTO SELECT

.

TO SET THE BAROMETER:

When the Display is first powered up, the pressure reading will be the actual pressure
1. The display is in the setup mode.
2. Press 

BAROMETER.

  The display will show            or           . 

3. Press

 BAROMETER 

again.  The display will show  the current 

absolute

 pressure.

4. Call a local airport for the current sea-level pressure.

5. Press MAX or MIN to change barometer reading up or down to the current  

sea-level pressure. The barometer may be adjusted up or down by 16.00 
inches of Mercury ( 524  millibars).  This is a one-time setting the system will 
remember  even if power is lost.

THE BACKUP BATTERY:

Provision is made for a 9 volt battery to provide continued operation in the event
of a power outage.  This battery may be a 9 volt alkaline, Ni-cad or Ni-MH battery
the display does not have a built-in charger, rechargeable batteries must be charged
periodically. The display is turned off to conserve power during a power outage.
However, any sensor value can be viewed by pressing and holding the touch switch 
for that sensor.  

You do not have to install a battery for normal operation. 

The 

battery is only necessary to maintain the correct time and to record new maximums 
and minimums during an outage. A good quality alkaline battery should provide 
approximately 4 hours of operation.

RESETTING THE DISPLAY:

Press and hold RAINFALL;  Press MIN.  The processor will be reset.  The display will blank.

“1” indicates that the barometer is in Millibars.

rainfall is in millimeters.

“1” indicates that the wind speed is in kilometers per hour.  “2” indicates

PRESS 

WIND SPEED.

 The display will show:

TO VIEW RELATIVE HUMIDITY AND DEW POINT

       

1.  Press 

HUMIDITY

.  The display will show the

 Humidity

.

TO VIEW TEMPERATURE and WIND CHILL

       

1.  Press 

TEMPERATURE.

  The display will show the

 Temperature

.

2.

2.

Press 

HUMIDITY

 again.  The display will show the 

Dew Point

.  

Press 

TEMPERATURE 

again.  The display will show the

 Wind Chill            .

  

INSTALLATION AND 
OPERATING INSTRUCTIONS 
FOR THE WIRELESS

 

Weather Oracle°

MOUNTING THE DISPLAY:

The display may be wall mounted using the keyhole slots provided. An angle foot 
replacing the battery cover may be installed in place of the battery cover when it is 
desired to place the display on a desk or table. The black box containing the receiver 
is connected to the display with a 5 foot cable.  This, plus the cable from the wall 
transformer allows over 10 feet from a power outlet to the display. The output from 
the wall transformer is low voltage (9 volts DC).  When power is connected to the 
display, it will show dashes in the sensor display fields.  Within about 30 seconds, 
the display should show the proper sensor values. If this does not happen, it means 
that no information is being received from the sensor assembly.

The display incorporates a non-volatile memory in which the maximum, minimum  
and rainfall values are stored. Therefore, on initial start-up, these values may need 

The setup mode is used to:

1.  Set the time and date.
2. Set the displays to read English or Metric.

3.

Adjust the Temperature or Barometer.

1. Press and hold

 AUTO SELECT.

2.

 

WHILE HOLDING

 AUTO SELECT, 

press 

MAX

. The display will show 

 

12:00 if this is the original setup or if there is no backup battery and 

 

there has been a power outage. Otherwise  it will show the correct time.  

 

   

 

The

 MAX

 and

 MIN

 LED’s will be on and the colon will be blinking.

3. You are now in the setup mode.

Once the display has been placed in the setup mode, you can exit at any time by
pressing 

AUTO SELECT

TO SET THE CLOCK:

1.

 

Press

 MAX.

  The hours will flash.

2. 

Press 

MAX

 to increase the hours. Press 

MIN

 to decrease the hours.

3. 

Press

 AUTO SELECT.

  Minutes will flash.

4. 

Press 

MAX

 to increase the minutes. Press 

MIN

 to decrease the minutes.

5. 

Press 

AUTO SELECT.

 The month will flash.

6. 

Press 

MAX

 to increase the month. Press 

MIN

 to decrease the month.

7. 

Press 

AUTO SELECT.

 The day will flash.

8.

Press

 MAX

 to increase the day.  Press 

MIN

 to decrease the day.

9.

Press

 AUTO SELECT.

  The display will return to the setup mode.   

The display will show the time with the colon flashing.  If you wish to exit 
 the setup mode press 

AUTO SELECT. 

TO SET THE DISPLAYS FOR ENGLISH OR METRIC

 (DISPLAY IN THE SETUP MODE)

:

TEMPERATURE, DEW POINT AND WIND CHILL  

1.     The display is in the setup mode.

Press

 TEMPERATURE.

  The display will show            or           .   

“0” indicates that the temperatures are in Fahrenheit.  "1" indicates that the 

2.

3.

Press 

MAX

 or

 MIN

 to change from Metric or English.

4. 

 If you are finished with the setup mode, press 

AUTO SELECT.

 

to be reset.

TO PLACE THE DISPLAY IN THE SETUP MODE:

temperatures are in Celsius.

Reviews: