28
Location of chimney terminals
Dimension Terminal Position
Distance (mm)
A*
Directly under an opening, an open window or ventilation duct
600
B
Above an opening, an open window or ventilation duct
300
C
Alongside an opening, opening window etc.
400
D
Under gutter, earth pipes or drainpipes
300
E
Under eaves
300
F
Under balconies or carport roof
600
G
From a vertical drainpipe or earth pipe
300
H
From an internal or external corner
600
I
Overground roof or balcony level
300
J
From a surface facing the terminal
600
K
From a terminal facing the terminal
600
L
From an opening in carport (e.g., door, window into the dwelling)
1200
M
Vertical from a terminal on same wall
1500
N
Vertical from a terminal on same wall
300
P
From a vertical construction on the roof
600
Q
Above the intersection with roof
300
* In addition, the terminal must not be closer than 300 mm to an opening in the building, such as a
window or a door.
English
RAIS/
attika
- User manual for Q-Tee II Gas / Q-Tee II C Gas
Summary of Contents for Q-Tee II GAS
Page 2: ......
Page 35: ...35 Log 3 Log 4 Log 5 English RAIS attika User manual for Q Tee II Gas Q Tee II C Gas ...
Page 49: ...49 English RAIS attika User manual for Q Tee II Gas Q Tee II C Gas ...
Page 50: ...50 English RAIS attika User manual for Q Tee II Gas Q Tee II C Gas ...
Page 76: ...76 Français ...
Page 77: ...A A A 598 590 I E 250 D 50 149 M 76 460 410 582 291 291 149 Q Tee II Gas ...
Page 82: ...82 ...
Page 83: ...83 A A A E 250 D 50 330 179 660 479 598 590 76 460 179 M 330 Q Tee II C Gas ...
Page 91: ......