Control
If the ash is white and the walls in the combustion chamber are soot free after the stove
has been used, the air regulation was set correctly and the wood was sufficiently dry.
Using the wood burning stove
Adjusting the air damper. The damper has 3 settings.
Position 1
The damper is closed meaning that there is no air
intake.
Position 2
Push the lever until the first click. This position
gives full secondary air.
During normal use the lever is set between position
1 and 2.
When the flames are clear and yellow, the damper
is set correctly, i.e. resulting in a slow/optimal
burning.
Position 3
Pull the handle out, and push it to the right.
The air damper is completely open and gives full
primary and secondary air. This position is for the
lighting stage and is not used under normal
operation.