ENGLISH RAIS - manual for GEO
8
If it is found that there is excessive draught in the chimney then either an adjustable flue
damper or alternatively a draught stabiliser should be fitted. The adjustable flue damper
should not close off the flue entirely but should in its closed position leave a minimum
continuous opening free area of at least 20 % of the total cross sectional area of the flue or
fluepipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping
the chimney and connecting fluepipe.
You should also familiarise yourself with the draught conditions for chimneys with 2 flues.
The flue outlet spigot is 150 mm in diameter.
For strong draughts, the chimney or flue should be fitted with a draught stabiliser. In which
case, it is important to ensure that there is a free flow-through area of minimum 20 cm² when
the regulating gate is shut. Otherwise, the fuel energy may not be used optimally. If, at any
time, you are unsure about the condition of the chimney, you should contact a chimney
sweep.
Remember that access to the access door should be kept clear.
Summary of Contents for GEO
Page 1: ...ENGLISH RAIS manual for GEO 1 U S E R M A N U A L RAIS GEO ...
Page 2: ...We cannot be held responsible for any misprints ...
Page 14: ...ENGLISH RAIS manual for GEO 14 Step 3 Step 2 ...
Page 15: ...ENGLISH RAIS manual for GEO 15 Step 5 Step 4 ...
Page 17: ...ENGLISH RAIS manual for GEO 17 Step 3 Step 2 ...
Page 18: ...ENGLISH RAIS manual for GEO 18 Step 5 Step 4 ...
Page 23: ...ENGLISH RAIS manual for GEO 23 ...
Page 35: ...ENGLISH RAIS manual for GEO 35 ...
Page 37: ...ENGLISH RAIS manual for GEO 37 ...
Page 38: ...ENGLISH RAIS manual for GEO 38 ...
Page 39: ...ENGLISH RAIS manual for GEO 39 ...
Page 40: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Danmark www rais dk ...