12
US English User Manual for RAIS Rondo, RAIS Mino II and RAIS Mino II Soapstone
Clearance to combustible walls
To find out whether the wall by which the stove is to be placed is
combustible or not, please contact your architect or the local building
authorities.
If the floor is combustible, the stove must be placed on a non-com-
bustible plate such as steel, glass or stone.
Ref. Description
Minimum clearence
A
Sidewall to unit
13” (33 cm)
B
Backwall to unit
6.5” (16.5 cm)
C
Cornerwall to unit
6” (15.2 cm)
D
Sidewall to connector
20” (50.8 cm)
E
Backwall to connector
12” (30.5 cm)
F
Cornerwall to connector
14” (35.6 cm)
G
Ceiling to appliance
43,5” (111 cm)
H
Backwall to unit
13” (33 cm)
I
Backwall to connector
20” (50,8 cm)
J
Sidewall to unit
34” (86,4 cm)
K
Sidewall to connector
41” (104 cm)
L
Distance to frontwall/furnishing
34” (86.4 cm)
M
Cornerwall to connector
41” (104 cm)
Clearance to non-combustible wall
We recommend a minimum clearance to non-combustible material of
at least 50 mm so that cleaning is easy. The cleaning door should be
accessible at all times.
Clearances may only be reduced by means approved by the regulatory
authority.
**:
Please refer to NFPA guide-
lines in USA and CAN/CSA
B365-M91 in Canada.