22
English RAIS/
attika
- User Manual Q-BE INSERT
Malfunctions
Smoke spillage around door
May be caused by too weak draft in the chimney <12Pa
• check the flue or chimney for clogging
• check whether the extraction hood is switched on; if it is, switch it off and open a win-
dow/door in the proximity of the stove for a short while.
Soot on glass
May be caused by
• the firewood being too wet
ensure the proper heating of the stove when lighting, prior to closing the door
Stove is burning too strong
Possible cause:
• leak around the door seal
•
chimney draught too strong (>22 Pa), draught regulator should be installed
Stove is burning too weakly
Possible cause:
• insufficient amount of wood
• insufficient air supply for room ventilation
• failure to clean the flue ducts
• leaky chimney
• leakage between chimney and flue
NOTE!
Be careful when replacing the smoke converter plate and the smoke barrier.
Remove dirt and dust, and mount the
parts in reverse order.