19
US English
User Manual Q-Tee II USA / Q-Tee II C USA
**:
Please refer to NFPA guidelines in
USA and CAN/CSA B365-M91 in
Canada.
D
Ad
ja
ce
nt
w
al
l
45° to Wall
Adjacent wall
Parallel to Wall.
Back wall
Si
de
w
al
l
Clearances to combustible surfaces
**Rear/Top vent option
Ceiling
**
FLOOR PROTECTOR
See further floor protection requirements at bottom of this label.
Floor protection for
Canada: 30" (76 cm)
from unit to front of floor protector.
Floor protector must be under the pipe and 2"
(5cm) beyond each side for back venting.
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply
with 2020 particulate emission standards using crib wood. 0.9
g/hr, Method 28R
MINIMUM CLEARANCE Rear Vent
With Pedestal With Pedestal No pedestal
A: SIDE WALL TO UNIT 14"/356mm 14"/356mm 15"/381mm
B: BACK WALL TO UNIT 12"/305mm 12"/305mm 15"/381mm
C: CORNER WALL TO UNIT 13.5"/343mm N/A 15.5"/394mm
D: CEILING HEIGHT 45"/1143mm 45"/1143mm 45"/1143mm
E: FRONT WALL / FURNISHING: 36"/915mm 36"/915mm 36"/915mm
F: Back Wall to Pipe 17"/432mm N/A 20"/508mm
G: Side Wall to Pipe 24"/610mm 24"/610mm 25/635mm
H: Corner Wall to Pipe 22.5"/572mm N/A 24.5"/622mm
Do not store wood logs or combustible materials underneath the room heater
Écartement minimum Évent arrière
Avec piédestal Avec piédestal Sans piédestal
A: Mur latéral - Appareil 14"/356mm 14"/356mm 15"/381mm
B: Mur arriére - Appareil 12"/305mm 12"/305mm 15"/381mm
C: Mur de coin - Appareil 13.5"/343mm N/A 15.5"/394mm
D: Plafond - Lappareil 45"/1143mm 45"/1143mm 45"/1143mm
E: Distance meuble devant 36"/915mm 36"/915mm 36"/915mm
F: Paroi arrière de cheminée 17"/432mm N/A 20"/508mm
G: Paroi arrière de cheminée 24"/610mm 24"/610mm 25"/635mm
H: Coin mur pour cheminée 22.5"/572mm N/A 24.5"/622mm
Ne pas stocker les journaux de bois ou des matériaux combustibles sous le radiateur de la chambre
FLOOR PROTECTION:
Floor protection requirements are dependent upon whether the optional High Socket
Base, Rais part number 838040590 is used;
Floor protection must be non-combustible material extending beneath the stove,
and to the front and sides from door opening and to the rear as indicated.
The floor protection needed on the floor when used WITHOUT the base is required to have
thermal protection with an R value of 3.19 Btu*in/Hrs*ft2*°F (equal to 0.46 w/mk in SI units).
with the base, the floor protection is not required to have thermal protection (R=0)
Replace glass with only Rais authorized dealer supplied ceramic glass
** Not Tested - NFPA Guidelines in USA, CAN/CSA B365-M91 in Canada
** Non testé - NFPA Guidelines au USA, CAN/CSA B365-M91 au Canada
La protection de sol doit être au moins de 3/8 inch matériel non combustible placé sous le foyer
s'étendant vers l'avant, les côtés les ouvertures et l'arriére comme induqué.
Manufactured by:
RAIS A/S
Industrivej 20, DK-9900 Frederikshavn, Denmark
Model: Q-Tee II C USA
Solid Fuel Room Heater
Tested to:
UL 1482-2011
ULC S627-00
For Use With Solid Wood Fuel Only
Model
Modéle
Date of manufacture Month
Date of fabrication Mois
Year
Année
Serial no.
N° de série
Report No. #0138WS016S
Made in Denmark
Fabriqué au Danemark
Front
8"
8"
8"
2
4
"
This wood heater needs periodic inspection and repair for proper operation.
Consult the owner's manual for further information. It is against federal
regulations to operate this wood heater in a manner inconsistent with the
operating instructions in the owner's manual.
2"
C
C
H
H
F
B
A
G
E