ENGLISH RAIS - Manual for Rais Topas & Opus
Installation distance in case of combustible wall
To find out whether the wall next to where the stove is going to be installed is flammable,
you should contact your building contractor or the local building authorities.
The hearth should be able to accommodate the weight of the stove. The chimney must be
independently supported by wall brackets or a ceiling support plate. The weight of the stove
is indicated in the brochure.
The stove should always be installed on a non-combustible hearth of a size and construction
that is in accordance with the provisions of the current UK Building Regulations Approved
Document J.
If the stove is to be installed on a wooden floor, it must be covered with a noncombustible
material at least 12mm thick, in accordance with UK Building Regulations Approved Docu-
ment J, to a distance of 300 mm in front of the stove and 150 mm to each side measuring
from the door of the combustion chamber.
The clearance distances to combustible material beneath, surrounding or upon the hearth
and walls adjacent to the hearth should comply with the guidance on the separation of com-
bustible material given in UK Building Regulations Approved Document J and also in these
stove instructions.
Summary of Contents for TOPAS
Page 1: ...1 ENGLISH RAIS Manual for Rais Topas Opus U S E R M A N U A L RAIS TOPAS RAIS OPUS...
Page 2: ...We cannot be held responsible for any misprints...
Page 10: ...10 ENGLISH RAIS Manual for Rais Topas Opus...
Page 23: ...23 ENGLISH RAIS Manual for Rais Topas Opus...
Page 33: ...33 ENGLISH RAIS Manual for Rais Topas Opus 1 3 9 8 12 13 15 11 10 14 2 4 5 6 7...
Page 35: ...35 ENGLISH RAIS Manual for Rais Topas Opus 2 1 11 14 9 7 4 10 8 13 6 12 3 5...
Page 36: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn www rais dk...