Raisecom
ISCOM RAX711 (B)Product Description
Raisecom Technology Co., Ltd.
11
Table 3-1
Prints
No.
Description
1
-100-200V
AC power interface
2
-48V
DC power interface
3
PWR2, PWR1, SYS, MGT
Power LED 2
Power LED 1
System working status LED
Fast deployment LED
4
CONSOLE
Console interface (RJ45)
5
SNMP, 100M, and LNK/ACT
SNMP interface (RJ45)
6
IN, OUT, CLK, and LOS(only
for ISCOM RAX711-CLK)
Ingress interface for clock synchronization
signal
Egress interface for clock synchronization
signal
Clock synchronization LOS LED
7
1000M, LNK/ACT, and NNI
Service uplink interfaces (SFP)
8
1000M, LNK/ACT, and UNI
Service downlink interfaces (Combo)
9
ESD sensitive symbol
3.2 Interfaces
3.2.1 Service interfaces
Table 3-2 lists types and usage of service interfaces on the ISCOM RAX711(-CLK).
Table 3-2
Service interfaces
Interface
Name
Type
Description
0/1–0/2
Service uplink
interface
SFP
The interface supports the
following optical modules:
1000BASE-X
100BASE-FX
1/1–1/4
Service downlink
interface
Combo optical
interface (SFP)
The interface supports the
following optical modules:
1000BASE-X
100BASE-FX
The interface supports the
following electrical modules:
10/100/1000BASE-T