Air cleanliness
No explosive, conductive, magnetic, and corrosive dust is around the ISCOM RAX711 during
transportation.
Table 5-10 lists mechanical active substance requirements for the ISCOM RAX711 during
operation.
Table 5-10
Mechanical active substance requirements during operation
Mechanical active substance
Value
Number of dust grains (/m³
)
≤ 3 × 10
5
Floating dust (mg/m³
)
≤ 0.2
Droppable dust (mg/m²
·
h)
≤ 15
Grit (mg/m³
)
≤ 100
Table 5-11 lists chemical active substance requirements for the ISCOM RAX711 during
operation.
Table 5-11
Chemical active substance requirements during operation
Chemical active substance
Value
Sulfur dioxide SO
2
(mg/m³
)
≤ 0.30
Hydrogen sulfide H
2
S (mg/m³
)
≤ 0.10
Ammonia NH
3
(mg/m³
)
≤ 3.00
Chlorine Cl
2
(mg/m³
)
≤ 0.10
Chlorhydric acid HCl (mg/m³
)
≤ 0.10
Hydrofluoric acid HF (mg/m³
)
≤ 0.01
Ozone O
3
(mg/m³
)
≤ 0.05
5.7 Compliant standards and protocols
Table 5-12 lists standards and protocols complied with by the ISCOM RAX711.
Table 5-12
Compliant standards and protocols
Standard
Description
MEF
MEF6.1
Metro Ethernet Services Definitions Phase 2