Item
Description
Model
Symmetric twisted pair cable-100ohm-enhanced Cat 5 cable-
0.52mm-24AWG-8PIN
Number of cores
8
Table 6-14 lists PINs definitions of the clock cable for the 2 Mbit/s or MHz interface for the
ISCOM RAX711.
Table 6-14
PINs definitions of clock cable for 2 Mbit/s or MHz interface
Starting from (RJ45)
Ending at
Color
Remark
PIN 1 (DSR)
PIN 4
White/Orange
Twisted-
pair
PIN 2 (RTS)
PIN 5
Orange
PIN 3 (GND)
PIN 3
White/Green
Twisted-
pair
PIN 4 (TXD)
PIN 1
Green
PIN 5 (RXD)
PIN 2
Blue
Twisted-
pair
PIN 6 (DCD)
PIN 6
White/Blue
PIN 7 (CTS)
PIN 7
White/Brown
Twisted-
pair
PIN 8 (DTR)
PIN 8
Brown
6.2 SFP modules
6.2.1 100BASE-FX SFP optical module
Table 6-15 lists parameters of the 100BASE-FX SFP optical module.
Table 6-15
Parameters of 100BASE-FX SFP optical module
Model
Wavelength
(nm) (Laser
type)
Rx
type
Tx
optical
power
(dBm)
Minimum
overload
point (dBm)
Extinction
ratio (dB)
Rx
sensitivity
(dBm)
Transmission
distance (km)
USFP-
03/M-D-R
1310 (LED)
PIN
-20 to -
10
-14
9
-29
2
USFP-
03/S1-D-R
1310 (FP)
PIN
-15 to -
8
-8
9
-34
15
USFP-
03/S2-D-R
1310 (DFB)
PIN
-5 to 0
-8
9
-34
40