Raisecom
ISCOM6800 (A)Hardware Description
3 Cards
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
20
3.5.4 LEDs
There 17 LEDs on the GP16 card.
Table 3-21 lists LEDs on the GP16 card.
Table 3-21
LEDs on the GP16 card
LED
Quantity Status
Description
SYS/ALM
1
Green
System working status LED
Fast blinking green (4 Hz): the system is being
initialized.
Slow blinking green (1 Hz): the system is
working properly.
Off/Green: the system is working improperly.
Red
Alarm LED
Red: a fault is generated.
Blinking red: the card is inserted improperly.
Off: no fault is generated.
Orange
Standby LED
Orange: the card is in standby status.
Off: the card is not in standby status.
When the card is in standby status, other
LEDs are off.
LNK1–
LNK16
16
Green
PON interface working LED
Green: the interface is properly connected and a
successfully-registered ONU is working on the
interface.
Off: the interface is disconnected or no ONU is
successfully registered
3.5.5 Technical specifications
Table 3-22 lists technical specifications of the GP16 card.
Table 3-22
Technical specifications of the GP16 card
Parameter
Description
Dimensions
391 mm (Width) × 225 mm (Depth) × 22.16 mm (Height)
Weight
1.05 kg
Maximum power
consumption
70 W