ISCOM6800 (A)Hardware Description
4 Cables
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
38
To connect the fiber, align the head of the fiber with the optical interface and insert the
fiber into the interface gently.
To remove the fiber, press down the clamping connector, and push the fiber head
inwards, and then pull the fiber out.
SC/PC fiber connector
Figure 4-2 shows the appearance of the SC/PC fiber connector.
Figure 4-2
SC/PC fiber connector
When connecting or removing the SC/PC fiber connector, align the connector with the optical
interface, and do not rotate the fiber. Do as below:
To connect the fiber, align the head of the fiber with the optical interface and insert the
fiber into the interface gently.
To remove the fiber, push the fiber head inwards, and then pull the fiber out.
4.1.3 Wiring
Table 4-3 lists the wiring of the fiber.
Table 4-3
Wiring of the fiber
Wiring
relationship
Local optical interface
Direction of
optical signals
Peer optical interface
Single-fiber
connection
Optical interface
<->
Optical interface
Dual-fiber
connection
Optical interface Tx
->
Optical interface Rx
Optical interface Rx
<-
Optical interface Tx
4.2 Ethernet cable
4.2.1 Introduction
The Ethernet cable of the ISCOM6800 can be used to:
Connect the Ethernet electrical interface of the ISCOM6800 to other devices.