http://www.raisecom.com

   

 

- 16 - 

3.

 

If the modem is not working in pairs, it is required that the other brand equipment be 

configured exactly the same as the local modem, including PCM30/31 format, CRC 

enable/disable, and timing resource etc. If these parameters are properly configured, then 

please pay attention to the V.35 data engrossment in frame format. Refer to Chapter 1.3.4 for 

timeslot engrossment and ensure that both equipments have the same configuration. 

4.

 

After success of the second step (or ensure the 3

rd

 step), it is indicated that the 

communication link between local and remote equipments is working properly. Now, if the 

remote V.35 interface is connected properly but still cannot communicate normally, please 

adjust the TX CLK or RX CLK phase option on remote modem (or converter). 

If the link still remains disconnected, please contact the technical support from the local 

distributors. It is strongly suggested users present a report of the encountered problems along with 

network topology, and the test details of the above four steps, and email the report to the technical 

support. 

4.3 Fault-pass-through Function 

If LAL alarm appears, DCD signals will be disconnected at V.35 interface, and the DTE shall 

response that. 

If RAL alarm appears, CTS signals will be disconnected at V.35 interface, and the DTE shall 

response that. 

4.4 FAQs 

If there is any problem during installation and operation, please try the following solutions. If the 

problems still cannot be solved, please contact distributors for technical support. 

 

‹

 

Local Alarm Indicator is ON. 

Answer: It is possible that there is uplink alarm (AIS), loss of frame (LOF), or CRC alarm 

appearing on the modem. It indicates that the signal received is abnormal. Please check the link 

quality and interface parameter at the remote site. 

 

‹

 

Remote Alarm Indicator is ON. 

Answer: It is because there is receiving alarm at the remote site. The signal is send by the remote 

interface converter RC903-V35FE1. 

 

‹

 

Optical Interface LLOS (RLOS) is ON. 

Answer: Receiving signal at optical interface is lost. Please check if the optical input (RX) is 

connected, or reversely connected. Users can use the optical power meter to test the receiving 

optical power to check if it is above the threshold of optical receiving sensitivity. 

 

‹

 

Optical Interface LLOF (RLOF) is ON. 

Answer: Optical receiving signal is loss of frame. Optical signals are receiving but the optical 

power may be around the threshold. Please check the receiving optical power. If connects modem 

Summary of Contents for RC802-30B-FV35 series

Page 1: ...Raisecom Technology Co Ltd http www raisecom com 1 RC802 30B FV35 Series N 64K V 35 Interface Fiber Optic Modem User Manual Raisecom Technology Co Ltd...

Page 2: ...2 2 1 Point to point Fractional Mode Master Clock Slave Clock Topology 7 2 2 2 Point to point Fractional Mode Terminal Clock Slave Clock Topology 7 2 2 3 Point to point Transparent Mode Master Clock M...

Page 3: ...echnology Co Ltd http www raisecom com 3 CHAPTER 4 INSTALLATION AND TROUBLESHOOTING 15 4 1 CAUTIONS BEFORE APPLYING THE POWER SUPPLY 15 4 2 CONNECTION DIAGNOSIS 15 4 3 FAULT PASS THROUGH FUNCTION 16 4...

Page 4: ...the local site to realize the remote management 1 1 Main Features 1 2 Product Specifications 1 2 1 Fiber Optic Interface Specification Bit rate 100Mbps Line code 4B5B Fiber connecter SC Optical Transm...

Page 5: ...d No 16 timeslot shall be skipped if N is larger than 16 TS 1 TS 31 V 35 BANWIDTH TS N 1 TS 0 TS 16 1 2 4 Power Supply Power Supply DC 48V tolerance range from 36V to 72V AC 220V tolerance range from...

Page 6: ...m the fiber optic receiving link also called Restoring Clock Terminal Clock Mode The timing resource is provided by the DTE also called System Clock 2 1 2 Compatibility If RC801 30B FV35 is connected...

Page 7: ...shall work as DTE For the convenience of installation and test it is advised to set the local modem Master Clock Mode and remote modem Slave Clock Mode That is the timing resource is from the local m...

Page 8: ...modem which will convert the optical signals to G 703 compliant E1 electrical signals and then connect with a V 35 to fractional E1 interface converter Users can adopt Raisecom series interface conve...

Page 9: ...l link red ON receiving signal error occurs at local optical link include AIS LOF and CRC RAL Remote receiving signal error alarm in optical link red ON receiving signal error occurs at remote optical...

Page 10: ...r at the remote transmit and receive link then LAL and RAL can be used to indicate this alarm If users do not adopt Raisecom V 35 to fractional E1 interface converter i e RC903 V35FE1 then the RAL ind...

Page 11: ...erface Bandwidth Setup V 35 bit rate is N 64kbps N 1 31 when working at fractional E1 mode V 35 bit rate is 2048kbps when working at transparent E1 mode These 5 bits of the dip switch are actually rep...

Page 12: ...the above table for switch status Max bandwidth 1 is the maximum bandwidth in PCM30 Max bandwidth 2 is the maximum bandwidth in PCM31 3 2 2 The 6th Bit V 35 Bandwidth Control Option 6th bit Bandwidth...

Page 13: ...en configuring the timing resource V 35 DTE interface on Routers shall also be configured Both TX and RX clock shall be External Clock mode at V 35 interface that connected with Master Slave Clock equ...

Page 14: ...e link requirement The local and remote sites shall have the same configuration Loop back test is the auxiliary function used for users to test and diagnose the equipment and link Local Loop back is p...

Page 15: ...t not be reversely connected 4 2 Connection Diagnosis LERR or RERR indicator may be ON when just after connecting the optical fiber This is because a few error bits are generated by connecting cables...

Page 16: ...LAL alarm appears DCD signals will be disconnected at V 35 interface and the DTE shall response that If RAL alarm appears CTS signals will be disconnected at V 35 interface and the DTE shall response...

Page 17: ...resource setup 2 Check V 35 interface status of the Router if there are data errors on input and output then it indicates that TX CLKand RX CLK phase relationship need to be adjusted This problem can...

Page 18: ...raisecom com 18 BROADBAND To RAISECOM Copyright Declaration Raisecom Technology Co Ltd is the owner of this manual booklet The part or whole of this manual is not allowed to reproduce without Raiseco...

Reviews: