1.3.1 RC801-30B-FV35 Interconnection 

RC801-30B-FV35 series standalone dual-strand fiber optic modem shall work in pairs. 

1.3.2 Interconnection with Other Modems 

It is not suggested to connect RC801-30B-FV35 with other brand name N*64kbps V.35 interface 

fiber optic modems through optical link, but RC801-30B-FV35 can work with Raisecom’s other 

dual-strand fiber optic modems. 

Chapter 2. Recommended Connection Type 

2.1 Precautions before Connection 

2.1.1 Three Types of Timing Resource 

‹

 

Master Clock Mode: The timing resource is provided by the crystal oscillator inside the 

equipment, also called Internal Clock. 

‹

 

Slave Clock Mode: The timing resource is provided by recovering the clock from the fiber 

optic receiving link, also called Restoring Clock. 

‹

 

Terminal Clock Mode: The timing resource is provided by the DTE, also called System 

Clock. 

2.1.2 Compatibility 

If RC801-30B-FV35 is connected with G.703 interface fiber optic modem, and then connected 

with other brand name E1 fractional mode equipment (i.e. V.35 to fractional E1 interface converter, 

E1 interface Router); or such equipment as DXC and MUX is serially connected in the E1 link, 

the following requirements shall be noticed. 

1.

 

PCM30/31 format must be the same 

2.

 

The status of CRC enable/disable function must be the same 

3.

 

The V.35 signal bandwidth engrossment of G.704 frame pattern must match 

4.

 

Ensure that there is only one timing resource in the whole link. Other PCM equipment shall 

be configured to Slave Clock Mode (following the link clock). 

2.2 Basic Connection Type 

The connection topologies introduced in this part is only for user reference. Users are advised to 

Summary of Contents for RC802-30B-FV35 series

Page 1: ...Raisecom Technology Co Ltd http www raisecom com 1 RC802 30B FV35 Series N 64K V 35 Interface Fiber Optic Modem User Manual Raisecom Technology Co Ltd...

Page 2: ...2 2 1 Point to point Fractional Mode Master Clock Slave Clock Topology 7 2 2 2 Point to point Fractional Mode Terminal Clock Slave Clock Topology 7 2 2 3 Point to point Transparent Mode Master Clock M...

Page 3: ...echnology Co Ltd http www raisecom com 3 CHAPTER 4 INSTALLATION AND TROUBLESHOOTING 15 4 1 CAUTIONS BEFORE APPLYING THE POWER SUPPLY 15 4 2 CONNECTION DIAGNOSIS 15 4 3 FAULT PASS THROUGH FUNCTION 16 4...

Page 4: ...the local site to realize the remote management 1 1 Main Features 1 2 Product Specifications 1 2 1 Fiber Optic Interface Specification Bit rate 100Mbps Line code 4B5B Fiber connecter SC Optical Transm...

Page 5: ...d No 16 timeslot shall be skipped if N is larger than 16 TS 1 TS 31 V 35 BANWIDTH TS N 1 TS 0 TS 16 1 2 4 Power Supply Power Supply DC 48V tolerance range from 36V to 72V AC 220V tolerance range from...

Page 6: ...m the fiber optic receiving link also called Restoring Clock Terminal Clock Mode The timing resource is provided by the DTE also called System Clock 2 1 2 Compatibility If RC801 30B FV35 is connected...

Page 7: ...shall work as DTE For the convenience of installation and test it is advised to set the local modem Master Clock Mode and remote modem Slave Clock Mode That is the timing resource is from the local m...

Page 8: ...modem which will convert the optical signals to G 703 compliant E1 electrical signals and then connect with a V 35 to fractional E1 interface converter Users can adopt Raisecom series interface conve...

Page 9: ...l link red ON receiving signal error occurs at local optical link include AIS LOF and CRC RAL Remote receiving signal error alarm in optical link red ON receiving signal error occurs at remote optical...

Page 10: ...r at the remote transmit and receive link then LAL and RAL can be used to indicate this alarm If users do not adopt Raisecom V 35 to fractional E1 interface converter i e RC903 V35FE1 then the RAL ind...

Page 11: ...erface Bandwidth Setup V 35 bit rate is N 64kbps N 1 31 when working at fractional E1 mode V 35 bit rate is 2048kbps when working at transparent E1 mode These 5 bits of the dip switch are actually rep...

Page 12: ...the above table for switch status Max bandwidth 1 is the maximum bandwidth in PCM30 Max bandwidth 2 is the maximum bandwidth in PCM31 3 2 2 The 6th Bit V 35 Bandwidth Control Option 6th bit Bandwidth...

Page 13: ...en configuring the timing resource V 35 DTE interface on Routers shall also be configured Both TX and RX clock shall be External Clock mode at V 35 interface that connected with Master Slave Clock equ...

Page 14: ...e link requirement The local and remote sites shall have the same configuration Loop back test is the auxiliary function used for users to test and diagnose the equipment and link Local Loop back is p...

Page 15: ...t not be reversely connected 4 2 Connection Diagnosis LERR or RERR indicator may be ON when just after connecting the optical fiber This is because a few error bits are generated by connecting cables...

Page 16: ...LAL alarm appears DCD signals will be disconnected at V 35 interface and the DTE shall response that If RAL alarm appears CTS signals will be disconnected at V 35 interface and the DTE shall response...

Page 17: ...resource setup 2 Check V 35 interface status of the Router if there are data errors on input and output then it indicates that TX CLKand RX CLK phase relationship need to be adjusted This problem can...

Page 18: ...raisecom com 18 BROADBAND To RAISECOM Copyright Declaration Raisecom Technology Co Ltd is the owner of this manual booklet The part or whole of this manual is not allowed to reproduce without Raiseco...

Reviews: