14
Compatibility setting
This switch is designed to have this converter be compatible with RC901-FE4E1Rev. A and Rev. B.
When RC902-FX4E1-BL communicates with RC902-FE4E1 Rev. A and Rev. B, this switch should be
turned on to disable the new features of this version, such as remote loop back.
When this converter communicates with RC901-FE4E1 Rev. C, this switch should be turned off to enable
remote loop back. If this switch is turned on, the compatibility setting switch of RC901-FE4E1 Rev. C on
the other side of communication should also be turned on and remote loop back function will be disabled.
Setting the compatibility setting switch of both local and remote converters to “ON” is recommended when
communicating with Rev. C converter.
When this converter communicates with RC902-FE4E1 Rev. D, this switch should be turned off to enable
E1 remote loop back and remote network management through Raisecom network management platform.
Ethernet interface operating status setting
The default operating status of Ethernet interface is self-adaptation status with cross-connect
auto-recognition function. Users can modify Ethernet interface operating status by the setting in the
following table:
Connecting
device (network
card, switch, and
etc.) interface
Correct setting of converter Ethernet interface
10/100M
self-adaptive
interface
Keep the factory default setting, 100M full-duplex connection can be
achieved (frequently used connection)
Set converter operating status to 10M half-duplex, 10M half-duplex
connection can be achieved
Set converter operating status to 10M full-duplex, 10M full-duplex
connection can be achieved
Set converter operating status to 100M half-duplex, 100M half-duplex
connection can be achieved
10M half-duplex
interface
The operating status of the converter should be set to 10M half-duplex
mode, 10M half-duplex connection can be achieved
10M full-duplex
interface
Keep the factory default setting, 10M full-duplex connection can be
achieved
10M duplex
auto-negotiation
interface
Keep the factory default setting, 10M full-duplex connection can be
achieved
100M half-duplex
interface
The operating status of the converter should be set to 100M half-duplex
mode, 100M half-duplex connection can be achieved.