ON Enable
z
6
th
bit: setting for Ethernet data frame length
6
th
bit
Ethernet data frame length setting
ON 1916
byte
OFF 1536
byte
8 bit DIP-Switches on right side:
z
If auto-negotiation on from 1
st
through 4
th
Ethernet port, set duplex mode.
Note
: supports 10/100Mbps auto-adaptive Ethernet port and full/half duplex
auto-negotiation.
Auto-negotiation fail: set duplex mode of port referring to the 4bits switches
Auto-negotiation success: working on full duplex mode foreign to 4 bits switches setting.
Definition
1
st
2
nd
3
rd
4
th
OFF Full duplex
OFF
Full duplex
OFF
Full duplex
OFF
Full duplex
ON
Half duplex
ON
Half duplex
ON
Half duplex
ON
Half duplex
z
The 5
th
and 6
th
bit of Ethernet port: enable or disable insulation function of Ethernet port
5
th
6
th
Definition
OFF
OFF
1~4 can communicate each other, default setting
OFF
ON
1~4 Ethernet port isolated on local end
ON
OFF
1~4 port isolated oppositely both on two sides
(with TAG)
ON
ON
1~4 port isolated oppositely both on two sides
(without TAG)
‘
Communicate
’ means all users at 4 Ethernet ports of local end can communicate either each
other or with users at remote end.
“
Isolated on local end
” means users, at 4 Ethernet ports of local end, isolate each other; but can
communicate with users at remote end.
“
isolated oppositely on two sides
” means the 1
st
port of local end can communicate with the 1
st
port of remote end, the 2
nd
port of local end can communicate with the 2
nd
port of remote end, the
3
rd
port of local end can communicate with the 3
rd
port of remote end and the 4
th
port of local end
can communicate with the 4
th
port of remote end. Whether add TAG target or not as per users’
requirement.
If enable this function, require to configure both ends to “isolated oppositely
on two sides” simultaneously.
z
7
th
bit: NM control RS232/485 selectable switch
7
th
NM control selection
OFF RS232
control
ON RS485
control
If connect NM port of connection device LINKUP with computer serial port, whether use