when installing:
1) Take care of thermal insulation; piping and tanks insulation, if necessary (for example, styrofoam 50-100 mm, lecagrus
or equivalent) of the tank and piping area and on the sides still to frost limit (1), or a larger area than the surface of the
tank dimensions (2), taking into account a 60 degree angle on the presence of frost (isolated from the frost limit with a 60
degree angle to the upper).
2) Ensure that the ventilation / inlet pipe's maintenance capability (3) (if necessary) with a T-piece in the incoming pipe.
3) Make sure that abundance floods are with sufficient slope.
4) Vibrate ground layers, especially under all the inlet and outlet pipes (4) (20-30 cm in stock)
5) When installing with rubber seal, use a cup or similar drill hole for the right size, dense, vibrate
ground under the pipe.
1)
2)
3)
4)
2)