Other thing ground installation
In damp places, tanks should
be anchored
1) with pressure-impregnated planks or concrete posts which are placed above the waist in the tank planks (without
PA0.85 low with self-anchoring tanks) are included in standard delivery
2) further anchoring with ropes over the container or through the attachment hole (4000 kg to a concrete slab (eg 0.4 m
thick and the dimensions of the bottom of the container, concrete K-25 the top and bottom of sieve # 6K200, distance 50
mm , fortress (Ø min. 10 mm for the lower boundary of the net)
3) further with long (min. 3 m, tank on both sides of the trench must be at least 1 - 1.5 m wider than the tank on both
sides) anchor cloth (through tank fixing holes)
4) further with stainless steel rods and anchoring plates (rods through mounting brackets)
Anchoring methods suitable for all vertical tank models. If necessary, a combination of several methods can be used.
The exact dimensions of the tank are in a detailed drawing.