background image

WCM-D Instruction Manual

For programming information:

“Wired programming guide”

For further installation information:

Wired Application Sheet”

The WCM-D allows custom and third party switch plates to be used in place of a Rako wired
keypad (WCM/WK-EOS/WK-MOD etc).

The WCM-D will fit inside a single gang UK back box.  Up to eight switch inputs can be
taken per WCM-D.  The switch plate can be formed of Latching or Momentary Action
switches connected by short wires to terminals on the WCM-D.

Wiring Switches to the WCM

The WCM-D is wired into two pluggable sets of terminals.  The 8 way terminal block
connects to the Rako wired network formed of Cat5/Cat6 cable with cable allocations as set
out above. The ten way terminal block is used to wire between one and eight 3rd party
switch panels into the WCM-D. Inputs “A-H” are shorted to common to output commands
from the WCM-D.

Terminating the WCM-D

No Term (Unterminated)

Used when the WCM-D is not at the
end of line (with or without a
RAK-STAR). This is usually identifiable
by two cables being connectedto the
WCM-D.

WCM-D

Manual Version 2.0.0

Reviews: