32
UK/Plessey
Read:
Format
Data digits (variable) 2 check digits (optional)
Check digit verification: The UK/Plessey has one or two optional check digits. The check digit 1 and
check digit 2 will be calculated as the sum module 10 or 11 of the data digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of Code 39.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
SETUP
Option bar code
Option
Alpha. entry
Read
Disable
Enable
00*
01
Check digit verification
Disable
Enable
00
01*
Check digit transmission
Disable
Enable
00*
01
Max. code length
00-99
00-99
00*
Min. code length
00-99
00-99
01*
Code ID setting
00-FF
16
(ASCII)
00-FF
16
<U>*
Insert group selection
00-66
00-66
00*
Reserved
END