Warning
PMI304 mains connector has three wires (2 poles + earth). Earth should imperatively be connected
to mains earth.
Never use this equipement without proper grounding.
Check quality of grounding.
Should noise or hum occurs when connected to other equipments, never disconnect grounding,
use insulating transformer on mains.
Never open the case without disconnecting mains
Avoid high temperature exposure.
Never expose the equipment to rain, snow or moisture.
PMI304 complies with :
EN60065, EN55013, EN55020, EN60555-2, and EN60555-3, according to 73/23/EEC, 89/336/EEC
and 93/68/EEC.
INFORMATIONS
SPECIFICATIONS
Phantom power supply: 48 Volts
Power supply:
230 Volts +/- 10 %
50/60 Hz
Size:
220 x 44 x 150 mm
Weight:
1,5 kg
3 pts Fem XLR
3 pts Fem XLR
3 pts male XLR
Sub-D 9 Fem
Inputs
Connector
Type
Impedance
Sensitivity
Clipping
200 Ohms
matched
10 KOhms
-5 dBu / 435 mV for
-26 dBu sensitivity
+27 dBu / 17,3 V for
17 dBu sensitivity
+6 dBu / 1,54 V
+26 dBu / 15,4 V
+6 dBu / 1,54 V
+26 dBu / 15,4 V
Balanced
Balanced
Micro
Outputs
Connector
Type
Impedance
Nominal level
Maximum level
100 Ohms
470 Ohms
Distorsion: > 0,025 % for input level to 40 dBu and output level to +6 dBu.
Bandwidth: 12 Hz to 33 kHz at -1 dB.
Noise to the input:
micro input: - 133 dBu
with a
0
charge.
- 129 dBu with a 220
charge.
Balanced
Balanced
Micro
Line
Mix
-58 dBu / 0,97 mV
to -26 dBu / 39 mV
-24 dBu / 49 mV
to +7 dBu / 1,73 V