NOTE:
•
During engine shut down on vehicles equipped with
manual transmissions, it is normal for the diesel en-
gine to resonate heavily for a moment during engine
shut off. When the engine is connected to a manual
transmission, this resonance causes load gear rattle
from the transmission. This is commonly referred to as
“shut down rattle.” The manufacturer recommends
performing engine shut down with the clutch pedal
pushed to the floor (clutch disengaged). When engine
shut down is performed in this manner the rattle is
reduced (not eliminated).
•
Refer to the following chart for proper engine shut-
down.
Driving
Condition
Load
Turbo-
charger
Tempera-
ture
Idle Time
(min.)
Before
Engine
Shutdown
Stop and
Go
Empty
Cool
Less than
One
Stop and
Go
Medium
One
Highway
Speeds
Medium
Warm
Two
City Traffic
Maximum
GCWR
Three
Highway
Speeds
Maximum
GCWR
Four
Uphill
Grade
Maximum
GCWR
Hot
Five
4
STARTING AND OPERATING
173
Summary of Contents for Truck 2014
Page 1: ...R a m Tr u c k O W N E R S M A N U A L 2 0 1 4 D i e s e l S u p p l e m e n t...
Page 3: ...RAM DIESEL SUPPLEMENT RAM 1500 3 RAM 2500 3500 4500 5500 119 INDEX 315...
Page 4: ......
Page 5: ...RAM 1500...
Page 6: ......
Page 8: ......
Page 9: ...INTRODUCTION CONTENTS A MESSAGE FROM CHRYSLER GROUP LLC 8 1...
Page 16: ...INSTRUMENT CLUSTER 14 UNDERSTANDING YOUR INSTRUMENT PANEL...
Page 17: ...INSTRUMENT CLUSTER LARAMIE 3 UNDERSTANDING YOUR INSTRUMENT PANEL 15...
Page 36: ......
Page 110: ......
Page 120: ......
Page 121: ...RAM 2500 3500 4500 5500...
Page 122: ......
Page 124: ......
Page 125: ...INTRODUCTION CONTENTS A MESSAGE FROM CHRYSLER GROUP LLC 124 1...
Page 134: ...INSTRUMENT CLUSTER 132 UNDERSTANDING YOUR INSTRUMENT PANEL...
Page 154: ......
Page 239: ...WHAT TO DO IN EMERGENCIES CONTENTS JUMP STARTING 238 With Portable Starting Unit 241 5...
Page 244: ......
Page 290: ......
Page 316: ......
Page 317: ...INDEX...
Page 330: ...Chrysler Group LLC 14D241 226 AA First Edition Printed in U S A...