Adjusting Angle
Perform this procedure to adjust the position of the ventilator. Use your hand
to unscrew the tilt adjustment knob, and then lock it in place from above, and held in the
inclined position by tightening the knob. For negative tilt, use the negative tilt bracket. This
provides tilt up/down adjustment, from 0 to + 34 degrees.
For confined space rescue operations, you can place the ventilator directly on top of a
manhole. Tilt range from -90 to +90 degrees. Note that those positions can direct airflow
downward or upward
Negative tilt bracket
(Accessory)
0
o
-90
o
+90
o
34
o
Loosen
Tighten
Tilt adjustment knob
Connection of Battery Pack
DC Operation
• Plug the ventilator connector cable (blue) into the battery connector:
• Set the installation index on the battery with the cable, lining up with the cable
connector.
• Press the connector lock and rotate the blue piece clockwise (a quarter turn to the
right) in the most careful way possible.
• Align the edge of the battery pack with holder under the red line where it says, “Align
battery EX150Li” and firmly slide the battery in the direction of the arrow as shown in
the illustration until a loud click is heard.
Operational Modes
AC Operation
• Input Voltage. 90-250VAC, 50/60Hz
• The ventilator is capable of operating seamlessly in countries that supply electricity at
either 120V AC/60 Hz or 240V AC/50 Hz without manual adjustments by the user.
• Operation out of these limits can damage electrical components and will void the
warranty.
1. Connect the fan to an AC power source.
2. Status LED Light will automatically turn green, displaying the status “Ventilator is
connected on AC Power Supply”.
3. Start the ventilator by using the Speed Control knob to the desired speed.
Note: You can keep the batteries on their location without charging the battery.
Battery Indicator Lights will turn off because there is no battery charging
when ventilator is running on AC.
4. When the fan is powered off, Status LED Light will automatically turn off after 1 hour and
the battery Indicator Lights will redisplay battery charge level of each battery pack detected.
The ventilator will begin charging the battery packs after 60 minutes of idle time.