background image

14

15

AC PWR

PRESS

ON/OFF

PRESS FOR 

MAX

L

R

DC PWR
MAX
FAULT

L

BAT. FAULT

NO PWR

STORAGE

MODE

Intellisense

TM

 

E3

HI

OFF

LOW

AIRFLOW

LIGHTS

The Fuel Gauge

For batteries equipped with a battery fuel gauge:

The Battery Fuel Gauge provides battery status information using five red LEDs. 

 

Press the Fuel Gauge button to display the lights. The fuel gauge lights will remain lit for 

approximately five seconds. 

  

The numbers represent each LED and the grid is how they're laid out:

Fuel Gauge Lights

Diagnosis

Solution

LEDs 1-5: Red Solid

Remaining Run Time

Continue Working

LED 1: Red Flashing

LEDs 2-5: Off

Less than 13% run time left

Charge Pack

LEDs 1-5: Red Flashing

Battery Temperature too 

high

Allow Battery to Cool

35-55%56-76%

77-99%

100%

14-34%

Battery Status Indicator Lights

On the control panel there are 2 sets of lights: on the top side of the battery lights indicate 

the charge level in the battery attached to the left side of the ventilator, on the bottom side 

of the battery lights indicate the charge level in the battery attached to the right side of the 

ventilator.

 

If the battery is charging, the green indicator lights will horizontally scroll from left-to- right, 

turning solid green when the battery is fully charged.

If the ventilator is running on battery power, the estimated remaining battery time is 

shown.

If all the lights flash red, this indicates that the battery has failed and the battery must be 

replaced.

Battery Pack Protection

• To protect itself from damage and extend its life, the battery pack's intelligent circuit 

monitors current draw and temperature. In extreme situations, the battery pack will 

turn OFF the ventilator if the current draw becomes too high. All the fuel gauge lights 

will flash.  

• Under extreme circumstances, the internal temperature of the battery could become 

too high. If this happens, the fuel gauge lights will flash in an alternating pattern and 

the tool will not run. 

• While a battery undergoes a charge cycle, its temperature rises. To prevent grid 

corrosion and eventual battery failure, allow the battery to cool down in between 

charging and discharging.

1 2 3

4 5

Summary of Contents for EL6525

Page 1: ...trol 5 6 7 8 8 7 6 5 THE WRITTEN PERMISSION OF Euramco Safety Inc IS PROHIBITED Euramco Safety Inc ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Owner s Manual EX150Li HIGH PERFORMANCE BATTERY FAN ...

Page 2: ...ance ventilator manufactured in the USA by Euramco Group Inc For more than 50 years Euramco Group has been on the cutting edge of industrial fire and marine ventilation products Each of our blower exhausters PPV LSV fans and accessories represent the finest technologies available Every product is constructed to demanding and exact specifications for quality performance and reliability When human l...

Page 3: ...ower the ventilator The integrated battery chargers will charge one or two fully discharged battery packs in 6 hours or less LED scene lights are integrated into the ventilator shroud and have a 3 intensity infinite switch knob high low and off Turn to change The LED knob selects the scene lights output level in a row Clockwise Progression Off Full Half Off A Control Panel on the top of the unit c...

Page 4: ...le cord that allows the unit to operate up to 250 VAC Mainly used in Type Order North and Central America Japan B EL CUS 4762 France Belgium Germany Austria the Netherlands and most European countries E F EL CEU 4762 United Kingdom Ireland Malta Malaysia and Singapore Hong Kong Nigeria G EL 83070 4762 Australia New Zealand Papua New Guinea and Argentina I EL 84040 4762 China P R C I EL 84640 4762 ...

Page 5: ... under the red line where it says Align battery EX150Li and firmly slide the battery in the direction of the arrow as shown in the illustration until a loud click is heard Operational Modes AC Operation Input Voltage 90 250VAC 50 60Hz The ventilator is capable of operating seamlessly in countries that supply electricity at either 120V AC 60 Hz or 240V AC 50 Hz without manual adjustments by the use...

Page 6: ...ery packs each pack functions independently and is isolated from the other so that if one pack should fail open circuit short circuit or become discharged the other battery will provide power to operate the system When using dual batteries it s important that both batteries be of the same charge level and ideally of the same age and condition It s normal for one battery to discharge slightly more ...

Page 7: ...on 2 Batteries Speed Level Knob At maximum speed 45 minutes 11 At maximum speed and Max button activated 30 minutes Max button activated Charging Procedure Battery Fuel Gauge Make sure the battery pack is connect correctly into the ventilator as described above in Connection of Battery Pack The next step is to leave the ventilator off During charging the battery indicator lights will flash The bat...

Page 8: ...ttom side of the battery lights indicate the charge level in the battery attached to the right side of the ventilator If the battery is charging the green indicator lights will horizontally scroll from left to right turning solid green when the battery is fully charged If the ventilator is running on battery power the estimated remaining battery time is shown If all the lights flash red this indic...

Page 9: ...e charge 0o C to 40o C 32o F to 104o F A cold soaked battery may not power a fan or be able to take a charge If this occurs warm up cold battery at room temperature 20o C 68o F and try again Operating Limitations 1 AC power must be disconnected for Storage Transport Mode to be activated 2 Press and hold both the WAKE STOP and the MAX buttons together for 8 seconds until the status LED light change...

Page 10: ...used for 6 months check the charge status and either charge or dispose of the battery as appropriate Recommendations Battery packs will last significantly longer when run in pairs two battery packs per fan as there is 50 less discharge current per pack As with any equipment batteries will wear out faster with heavy use Depth of Discharge DoD determines the cycle count of the battery The smaller th...

Page 11: ... or any other heavy impact may compromise water ingress protection Quickly inspect for obvious damage after every use If damage is noted contact Authorized Service Center for inspection testing and maintenance Damage to gasket may compromise water ingress protection increasing risk of pack failure Do not store in same compartment with combustible or highly flammable material as gasoline and diesel...

Page 12: ...ces accessories RAMFAN s fire fighting PPV Series outperforms larger blowers in their class with their precision balanced TurboForce Impellers that maximize airflow These PPV blowers have proven to be effective in controlling airborne contaminates replacing interior air removing heat and supplementing fixed ventilation systems By pressurizing properly and controlling the resultant flow path these ...

Page 13: ...ue Edmond Reuter 5326 Contern Luxembourg Phone 352 621377200 Fax 352 26008056 theteam euramcosafety com MIDDLE EAST UAE Jebel Ali FTZ Dubai Phone 1 619 670 9590 x114 Fax 1 619 670 7345 theteam euramcosafety com CHINA No 128 HeZhou Road JiaoChuan Street ZhenHai District Ningbo China 315207 Phone 86 57487979390 Fax 86 57487979391 theteam euramcosafety com SINGAPORE 1 Fullerton Road 02 01 One Fullert...