background image

16

17

The Fuel Gauge

The Battery Fuel Gauge provides battery status information using five red LEDs. 

 

Press the Fuel Gauge button to display the lights. The fuel gauge lights will remain lit for 

approximately five seconds. 

  

The numbers represent each LED and the grid is how they're laid out:

1 2 3

4 5

Fuel Gauge Lights

Diagnosis

Solution

LEDs 1-5: Red Solid

Remaining Run Time

Continue Working

LED 1: Red Flashing

LEDs 2-5: Off

Less than 13% run time left

Charge Pack

LEDs 1-5: Red Flashing

Battery Temperature too 

high

Allow Battery to Cool

Less than 13% if bottom light is flashing 

35-55%56-76%

77-99%

100%

14-34%

Battery Status Indicator Lights

On the control panel there are 2 sets of lights: on the top side of the battery lights indicate 

the charge level in the battery attached to the left side of the ventilator, on the bottom side 

of the battery lights indicate the charge level in the battery attached to the right side of the 

ventilator.

AC PWR

PUSH FOR 

WAKE | STOP

PUSH FOR

MAX

L

R

DC PWR
DC MAX
FAULT

BAT. FAULT

NO PWR

STORAGE

MODE

Intellisense

TM

 

E3

LIGHTS

SPEED

MAX

 

If the battery is charging, the green indicator lights will horizontally scroll from left-to- right, 

turning solid green when the battery is fully charged.

If the ventilator is running on battery power, the estimated remaining battery time is 

shown.

If all the lights flash red, this indicates that the battery has failed and the battery must be 

replaced.

Battery Pack Protection

• To protect itself from damage and extend its life, the battery pack's intelligent circuit 

monitors current draw and temperature. In extreme situations, the battery pack will 

turn OFF the ventilator if the current draw becomes too high. All the fuel gauge lights 

will flash.  

• Under extreme circumstances, the internal temperature of the battery could become 

too high. If this happens, the fuel gauge lights will flash in an alternating pattern and 

the tool will not run. 

• While a battery undergoes a charge cycle, its temperature rises. To prevent grid 

corrosion and eventual battery failure, allow the battery to cool down in between 

charging and discharging.

Summary of Contents for EX150Li

Page 1: ...trol 5 6 7 8 8 7 6 5 THE WRITTEN PERMISSION OF Euramco Safety Inc IS PROHIBITED Euramco Safety Inc ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Owner s Manual EX150Li HIGH PERFORMANCE BATTERY FAN ...

Page 2: ...on 11 Connection of Battery Pack 11 12 Battery Operation Procedures 13 14 Run Time 14 Charging Procedure 15 The Fuel Gauge 16 Battery Status Indicator Lights 17 Battery Pack Protection 17 Storage Transport Modes 18 How to Activate Storage Transport Mode 18 AC Power Cord 19 Operating Limitations 19 Lithium Ion Battery Maintenance Guideline 20 Overview 20 Storage 20 Recommendations 20 Maintenance an...

Page 3: ...ets worldwide through five locations globally Warning Labels and Safety Instructions This is the safety alert symbol When you see this symbol on your ventilator or in this manual be alert to the potential for personal injury or damage to your equipment Be sure you understand all safety messages and always follow recommended precautions and safe operating practices Important safety information is p...

Page 4: ...SION OF Euramco Safety Inc IS PROHIBITED Euramco Safety Inc ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EL6500 2 WHL EL6500 2 WHL 2 EXTENDED HANDLE 1 1 FIRST ANGLE PROJECTION UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE INCHES MM TOLERANCES APPLY TO PRIMARY INCH DIMENSION AND ARE AS INDICATED RADII 015 MAX UNLESS SPECIFIED ON DRAWING PAR...

Page 5: ...n the ventilator Yellow Flashing STORAGE MODE Storage Transport Mode Plug Types The EX150Li is suitable for worldwide applications A voltage converter is not needed The unit includes a simple removable cord that allows the unit to operate up to 250 VAC Mainly used in Type Order North and Central America Japan B EL CUS 4762 France Belgium Germany Austria the Netherlands and most European countries ...

Page 6: ...it says Align battery EX150Li and firmly slide the battery in the direction of the arrow as shown in the illustration until a loud click is heard Operational Modes Input Voltage 90 250VAC 50 60Hz The ventilator is capable of operating seamlessly in countries that supply electricity at either 120V AC 60 Hz or 240V AC 50 Hz without manual adjustments by the user Operation out of these limits can dam...

Page 7: ...runtime and airflow performance When using two battery packs each pack functions independently and is isolated from the other so that if one pack should fail open circuit short circuit or become discharged the other battery will provide power to operate the system When using dual batteries it s important that both batteries be of the same charge level and ideally of the same age and condition It s...

Page 8: ...ll charge beforehand and also 100 efficiency Read Factors that affect Battery Life section 2 Batteries Speed Level Knob At maximum speed 45 minutes 11 At maximum speed and DC Max button activated 30 minutes Max button activated MAX Make sure the battery pack is connect correctly into the ventilator as described above in Connection of Battery Pack The next step is to leave the ventilator off During...

Page 9: ...R PUSH FOR WAKE STOP PUSH FOR MAX L R DC PWR DC MAX FAULT BAT FAULT NO PWR STORAGE MODE IntellisenseTM E3 LIGHTS SPEED MAX If the battery is charging the green indicator lights will horizontally scroll from left to right turning solid green when the battery is fully charged If the ventilator is running on battery power the estimated remaining battery time is shown If all the lights flash red this ...

Page 10: ...E STOP PUSH FOR MAX L R DC PWR DC MAX FAULT BAT FAULT NO PWR STORAGE MODE IntellisenseTM E3 LIGHTS SPEED MAX How to activate Storage Transport Mode AC Power Cord CORD STORAGE This battery fan was designed to replace corded AC fans optimizing cordless operations AC power cord is designed to be removable for the convenience of those users who choose to operate cordless AC power connector is a Push P...

Page 11: ...attery packs per fan as there is 50 less discharge current per pack As with any equipment batteries will wear out faster with heavy use Depth of Discharge DoD determines the cycle count of the battery The smaller the discharge low DoD the less stress is enacted on the chemistry of the battery and the longer the battery will ultimately last Ideally operators should avoid full discharges and charge ...

Page 12: ...n warrantable failures Maintenance Schedule Battery packs should be inspected regularly for mechanical damage Dropping or any other heavy impact may compromise water ingress protection Quickly inspect for obvious damage after every use If damage is noted contact Authorized Service Center for inspection testing and maintenance Damage to gasket may compromise water ingress protection increasing risk...

Page 13: ...ces accessories RAMFAN s fire fighting PPV Series outperforms larger blowers in their class with their precision balanced TurboForce Impellers that maximize airflow These PPV blowers have proven to be effective in controlling airborne contaminates replacing interior air removing heat and supplementing fixed ventilation systems By pressurizing properly and controlling the resultant flow path these ...

Page 14: ...ue Edmond Reuter 5326 Contern Luxembourg Phone 352 621377200 Fax 352 26008056 theteam euramcosafety com MIDDLE EAST UAE Jebel Ali FTZ Dubai Phone 1 619 670 9590 x114 Fax 1 619 670 7345 theteam euramcosafety com CHINA No 128 HeZhou Road JiaoChuan Street ZhenHai District Ningbo China 315207 Phone 86 57487979390 Fax 86 57487979391 theteam euramcosafety com SINGAPORE 1 Fullerton Road 02 01 One Fullert...

Reviews: