background image

SM-EFATEX Rev E  - Page 

FlowPath

™ 

Control

Euramco Group | 2746 Via Orange Way, Spring Valley CA 91978 USA  

Ph: +1-619-670-9590 | www.euramco.com

TECHNICAL INFORMATION AND ORIGINAL INSTALLATION 

INSTRUCTIONS

SM-EFATEX REV E

Portable Ventilators for 

Hazardous Locations

UB20xx EFi120xx

EFi75xx EFi150xx

Applicable Models:

The Portable Ventilators described herein are intended 

for use in Explosive Atmospheres in accordance 

with the limitations of the rating. It is the user’s 

responsibility to determine the suitability of equipment 

for the intended purpose.

II 2 G Ex db eb IIB T6 Gb

0539 Demko 09 ATEX 0926969X

IECEx UL 13.0062X

0539

Summary of Contents for FlowPath EFi120 Series

Page 1: ...E Portable Ventilators for Hazardous Locations UB20xx EFi120xx EFi75xx EFi150xx Applicable Models The Portable Ventilators described herein are intended for use in Explosive Atmospheres in accordance with the limitations of the rating It is the user s responsibility to determine the suitability of equipment for the intended purpose II 2 G Ex db eb IIB T6 Gb 0539 Demko 09 ATEX 0926969X IECEx UL 13 ...

Page 2: ...R IEC 60079 14 to a suitable safe power location or under one apparatus or enclosure in one of the protection concepts for use in hazardous locations Flying leads consist of a brown Hot wire blue Neutral wire and yellow green Ground wire T6 Temperature Classification 85 C T6 According to IEC 60079 0 EN 60079 0 ABNT NBR IEC 60079 0 To ensure that there is no risk of ignition due to hot surfaces the...

Page 3: ...t Voltage Frequency Impeller Motor part No UB20xx EF7002 EF8002 115 VAC 50 60 HZ 230 VAC 50 60 HZ Plastic 1933007415 1933007419 EFi75xx EB7201XX EB7201XX 230 115 VAC 50 60 HZ 230 VAC 50 60 HZ Metal 1133007405 EFi120xx EA8120XX 110 EA8120XX 110 VAC 50 HZ 240 VAC 50 HZ Plastic 1223007401 EFi150xx EG8200XX EG8200XX 230 115 VAC 50 60 HZ 230 VAC 50 60 HZ Plastic 1133007417 The Flame Proof Electric Moto...

Page 4: ...n Classification IP68 Temperature Range 4 F to 212 F Approval PTB 00 ATEX 1063 The power cables are not terminated with power plugs See Special Conditions for safe use The fans are assembled with both Inlet and Outlet Safety Guards that conform to the safety standards to prevent danger zones being reached by upper limbs in the BS EN ISO 12100 Safety Machinery Guards Standard Installation and Start...

Page 5: ...plication in a potentially explosive environment the ducting must be 1 Statically Conductive Surface resistance 106 ohms 2 Flexible 3 Reinforced with integrated helical steel wire spaced to prevent duct material from collapsing when airflow is inadvertently blocked on suction side of duct MAINTENANCE Disconnect power before inspection disassembly or cleaning Never immerse or directly spray motor w...

Page 6: ...compliance with electrical code Keep area clear of rock and debris Keep away from children WARRANTY Positive Pressure Ventilators Turbo Ventilators and portable blowers excluding motor and wear items are warranted for one year from date of original purchase to be free of defects in material and workmanship Electric motors are warranted by their respective manufacturers Wear items include feet fast...

Page 7: ...irflow also referred to as free air occurs at 0 mm 0 w g The first chart shows 4 performance curves for all four ATEX fans running on 50Hz AC power The second chart show 3 performance curves for three of the ATEX fans running on 60Hz Please note that the EFi120xx is not designed to run efficiently on 60Hz AC power and does not appear on the 60Hz chart for this reason Fan Performance Characteristic...

Page 8: ...SM EFATEX Rev E Page 7 of 13 Fan Performance Characteristic for Fans Running on 60Hz AC power ...

Page 9: ...ck Couple Canister with 8 x 25 Duct Antistatic FDT 0815CBB Duct 8 x 15 Antistatic with Belt and Belt FDT 0825CBB Duct 8 x 25 Antistatic with Belt and Belt EF0304X Duct Adapter 8 20cm DC8 Duct Coupler 8 Stainless Steel MED189XX Manhole Entry Device Conductive MED90XX MED 90 Elbow Conductive MED5100XX Manhole Entry Device MED Conductive Assembly MEDIUM MED Universal Mount EFi75xx FDT 1215CBB Duct 12...

Page 10: ...PTER KIT 8 EZ 16 3 E POWER CABLE 2 EF7019 PULL ROD 9 EF7105AC HOUSING CONDUCTIVE 3 EM F 33 60XPEX EF7002 ATEX MOTOR 10 ST010 STATOR 4 EM F 33 230VXP EF8002 ATEX MOTOR 11 ED0170 MOTOR MOUNTING RING 5 ED0170 MOTOR MOUNTING RING 12 BL011 IMPELLER 6 EX 312 RWB CORD STRAP 7 EZ 080305003CE JUNCTION BOX ...

Page 11: ...0 cm DUCT ADAPTER KIT 7 EZ 14 3E POWER CABLE 2 EB7018 EFi75xx SWITCH ROD 8 EA7007 ADAPTER CASTING C FACE 3 EZ CAP A027 PUSH CAP 9 EB7201XXHA 12 BLOWER HOUSING ASSY 4 EM F 75 60XPEX MOTOR 10 EZ 312 RWB CORD STRAP 5 EA7004 FLANGE 11 BL008 IMPELLER 6 EZ 080305002CE JUNCTION BOX EFi75XX EB7201XX EB7201XX 230 ...

Page 12: ...5 7 8 6 9 10 11 1 EA7116 16 40 cm DUCT ASSY INLET 7 EZ 312 RWB CORD STRAP 2 EC7018 SWITCH ROD 8 EG8200XXHA HOUSING ASSY 3 EM F1 5 60 50XPEX MOTOR 9 EA7007 ADAPTER CASTING C FACE 4 EA7004 FLANGE 10 BL914 IMPELLER 5 EZ 080305002CE JUNCTION BOX 11 EA7117 16 40 cm DUCT ASSY EXHAUST 6 EZ 14 3 AWG POWER CABLE ...

Page 13: ...5 7 8 10 11 9 6 1 EA7116 16 40 cm DUCT ASSY INLET 7 EZ 312 RWB CORD STRAP 2 EC7018 SWITCH ROD 8 EG8200XXHA HOUSING ASSY 3 EM F1 5 60 50XPEX MOTOR 9 EA7007 ADAPTER CASTING C FACE 4 EA7004 FLANGE 10 BL914 IMPELLER 5 EZ 080305002CE JUNCTION BOX 11 EA7117 16 40 cm DUCT ASSY EXHAUST 6 EZ 14 3 AWG POWER CABLE ...

Page 14: ...G DIAGRAM MOTOR LEADS LINE CORD Ground Screw Yellow Green wire from Motor Cord Black Wire 1 from Motor Cord Black Wire 2 from Motor Cord Ground Screw Yellow Green wire from Power Cord Brown Wire from Power Cord Blue Wire from Power Cord ...

Reviews: