Motor connections are made through a non-detachable cable, secured to the motor with 

an approved Flame Proof cable gland from the company Hawke, model 501/421/0/M20 

and complies with International Standards EN 60079-0, EN 60079-1, and EN 60079-7. The 

electric motor drives an aluminum or plastic fan blade which is enclosed in a plastic, statically 

conductive housing with a conductivity rating of <1 giga ohms. Connection to the motor is 

facilitated by a Terminal Block mounted in an Increased Safety/Flame Proof Enclosure rated

II 2 G Ex e II T6, from the company Rose Industries, Part Number 05080806, and covered 

under ATEX Certificate No. PTB 00ATEX1063. This box was designed to conform to 

International Standards EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0 and EN 61241-1. 

The enclosure features stainless steel grounding lugs, with a high heat silicon gasket.

The Flame Proof enclosure has attached, approved, explosion proof cable glands, as 

described below.

Rated:

 II GD Ex e II

Type: 

Polyamide Ex metric conforms to International Standards EN 60079-0, EN 60079-1, EN 

60079-7, EN 61241-0 and EN 61241-1.

Material: 

Polyamide 

  Color: 

Black/Blue

Grommet: 

NBR

 

 

 

 

Protection Classification: IP68

Temperature Range: 

-4°F to +212°F 

 Approval: 

PTB 00 ATEX 1063

The power cables are not terminated with power plugs. See Special Conditions for safe use.

The fans are assembled with both Inlet and Outlet Safety Guards that conform to the safety 

standards to prevent danger zones being reached by upper limbs in the BS EN ISO 12100 

Safety Machinery – Guards Standard.

Installation and Start-Up

During the installation and start-up of the RAMFAN blowers in areas where there is a risk of 

explosion:

• Design of the electrical installations must be in accordance with EN/IEC/ABNT NBR    

IEC 60079-14.

• Ensure power source is providing an electrical ground.

• Blowers must be integrated into a system in a way to support accessibility for  

 

regular maintenance.

• Blowers are designed for portable, nonfixed installation.  Blowers have no mount 

 

ing features to support rigid duct or fix installations.

• Perform careful inspection of each blower system to ensure ducting is securely  

 

attached to blower. All components of the blower system are made of electrically  

 

conductive material. It is very important to properly and securely attach each component to 

maintain a ground path.

• Ensure set-up, installation, operation and maintenance are performed only by  

 

properly trained personnel.

• Operation after a faulty installation or maintenance shall be considered as    

 

unintended use.

INSTRUCTIONS AND CARE

Summary of Contents for FlowPath EFi120 Series

Page 1: ...E Portable Ventilators for Hazardous Locations UB20xx EFi120xx EFi75xx EFi150xx Applicable Models The Portable Ventilators described herein are intended for use in Explosive Atmospheres in accordance with the limitations of the rating It is the user s responsibility to determine the suitability of equipment for the intended purpose II 2 G Ex db eb IIB T6 Gb 0539 Demko 09 ATEX 0926969X IECEx UL 13 ...

Page 2: ...R IEC 60079 14 to a suitable safe power location or under one apparatus or enclosure in one of the protection concepts for use in hazardous locations Flying leads consist of a brown Hot wire blue Neutral wire and yellow green Ground wire T6 Temperature Classification 85 C T6 According to IEC 60079 0 EN 60079 0 ABNT NBR IEC 60079 0 To ensure that there is no risk of ignition due to hot surfaces the...

Page 3: ...t Voltage Frequency Impeller Motor part No UB20xx EF7002 EF8002 115 VAC 50 60 HZ 230 VAC 50 60 HZ Plastic 1933007415 1933007419 EFi75xx EB7201XX EB7201XX 230 115 VAC 50 60 HZ 230 VAC 50 60 HZ Metal 1133007405 EFi120xx EA8120XX 110 EA8120XX 110 VAC 50 HZ 240 VAC 50 HZ Plastic 1223007401 EFi150xx EG8200XX EG8200XX 230 115 VAC 50 60 HZ 230 VAC 50 60 HZ Plastic 1133007417 The Flame Proof Electric Moto...

Page 4: ...n Classification IP68 Temperature Range 4 F to 212 F Approval PTB 00 ATEX 1063 The power cables are not terminated with power plugs See Special Conditions for safe use The fans are assembled with both Inlet and Outlet Safety Guards that conform to the safety standards to prevent danger zones being reached by upper limbs in the BS EN ISO 12100 Safety Machinery Guards Standard Installation and Start...

Page 5: ...plication in a potentially explosive environment the ducting must be 1 Statically Conductive Surface resistance 106 ohms 2 Flexible 3 Reinforced with integrated helical steel wire spaced to prevent duct material from collapsing when airflow is inadvertently blocked on suction side of duct MAINTENANCE Disconnect power before inspection disassembly or cleaning Never immerse or directly spray motor w...

Page 6: ...compliance with electrical code Keep area clear of rock and debris Keep away from children WARRANTY Positive Pressure Ventilators Turbo Ventilators and portable blowers excluding motor and wear items are warranted for one year from date of original purchase to be free of defects in material and workmanship Electric motors are warranted by their respective manufacturers Wear items include feet fast...

Page 7: ...irflow also referred to as free air occurs at 0 mm 0 w g The first chart shows 4 performance curves for all four ATEX fans running on 50Hz AC power The second chart show 3 performance curves for three of the ATEX fans running on 60Hz Please note that the EFi120xx is not designed to run efficiently on 60Hz AC power and does not appear on the 60Hz chart for this reason Fan Performance Characteristic...

Page 8: ...SM EFATEX Rev E Page 7 of 13 Fan Performance Characteristic for Fans Running on 60Hz AC power ...

Page 9: ...ck Couple Canister with 8 x 25 Duct Antistatic FDT 0815CBB Duct 8 x 15 Antistatic with Belt and Belt FDT 0825CBB Duct 8 x 25 Antistatic with Belt and Belt EF0304X Duct Adapter 8 20cm DC8 Duct Coupler 8 Stainless Steel MED189XX Manhole Entry Device Conductive MED90XX MED 90 Elbow Conductive MED5100XX Manhole Entry Device MED Conductive Assembly MEDIUM MED Universal Mount EFi75xx FDT 1215CBB Duct 12...

Page 10: ...PTER KIT 8 EZ 16 3 E POWER CABLE 2 EF7019 PULL ROD 9 EF7105AC HOUSING CONDUCTIVE 3 EM F 33 60XPEX EF7002 ATEX MOTOR 10 ST010 STATOR 4 EM F 33 230VXP EF8002 ATEX MOTOR 11 ED0170 MOTOR MOUNTING RING 5 ED0170 MOTOR MOUNTING RING 12 BL011 IMPELLER 6 EX 312 RWB CORD STRAP 7 EZ 080305003CE JUNCTION BOX ...

Page 11: ...0 cm DUCT ADAPTER KIT 7 EZ 14 3E POWER CABLE 2 EB7018 EFi75xx SWITCH ROD 8 EA7007 ADAPTER CASTING C FACE 3 EZ CAP A027 PUSH CAP 9 EB7201XXHA 12 BLOWER HOUSING ASSY 4 EM F 75 60XPEX MOTOR 10 EZ 312 RWB CORD STRAP 5 EA7004 FLANGE 11 BL008 IMPELLER 6 EZ 080305002CE JUNCTION BOX EFi75XX EB7201XX EB7201XX 230 ...

Page 12: ...5 7 8 6 9 10 11 1 EA7116 16 40 cm DUCT ASSY INLET 7 EZ 312 RWB CORD STRAP 2 EC7018 SWITCH ROD 8 EG8200XXHA HOUSING ASSY 3 EM F1 5 60 50XPEX MOTOR 9 EA7007 ADAPTER CASTING C FACE 4 EA7004 FLANGE 10 BL914 IMPELLER 5 EZ 080305002CE JUNCTION BOX 11 EA7117 16 40 cm DUCT ASSY EXHAUST 6 EZ 14 3 AWG POWER CABLE ...

Page 13: ...5 7 8 10 11 9 6 1 EA7116 16 40 cm DUCT ASSY INLET 7 EZ 312 RWB CORD STRAP 2 EC7018 SWITCH ROD 8 EG8200XXHA HOUSING ASSY 3 EM F1 5 60 50XPEX MOTOR 9 EA7007 ADAPTER CASTING C FACE 4 EA7004 FLANGE 10 BL914 IMPELLER 5 EZ 080305002CE JUNCTION BOX 11 EA7117 16 40 cm DUCT ASSY EXHAUST 6 EZ 14 3 AWG POWER CABLE ...

Page 14: ...G DIAGRAM MOTOR LEADS LINE CORD Ground Screw Yellow Green wire from Motor Cord Black Wire 1 from Motor Cord Black Wire 2 from Motor Cord Ground Screw Yellow Green wire from Power Cord Brown Wire from Power Cord Blue Wire from Power Cord ...