COPYRIGHT © 2019 SANDVIK MINING AND CONSTRUCTION OY
Page 54 - Maintenance
Replacing teeth
RPV14R, RPV22R, RPV29R, RPV39R, RPV53R, RPV75R
NOTICE! Any type of hardfacing welding on the interchangeable parts is not
recommended, since they are made of wear proof material and hard to weld.
Furthermore, the hardfacing welding would alter the flatness of the manufactured
parts, making the coupling in their housings difficult.
1. Place the product on the ground at a 30° incline so that the side with the tooth
to be replaced faces upward. Remove the fastening pin (2), together with the
hardened resin (5) with of the supplied pin extractor, striking the end with a
hammer (see illustration).
2. Extract the tooth (1) from its housing. Carefully clean the space (6), which
contained the resin, and eliminate any residue.
3. Place the product on the ground at a 30° incline so that, due to gravity, the tooth
will naturally come into contact with the adapter.
4. Once the tooth (1), is positioned on the adapter, insert the fastening pin (2) from
the back.
MB030012
MB030013
4
5
2
MB030014
6
1