13
EN
SOLUTION
CAUSE
INDICATOR
PROBLEM
Replace battery
Low battery
Sensor flashes
continuously
when user’s
hands are within
the sensor’s
range
No water
coming out
of the faucet
Increase the range
Range is too short
Light in the
sensor does not
flash once when
user’s hands
are within the
sensor’s range
Decrease the range
Range is too long
The battery must be replaced
Battery is completely used up
*Unit is in Security Mode
Eliminate cause of reflection
Sensor is picking up reflections from the
washbasin or another object
Connect the electronic unit
.connectors to the solenoid
Connectors between the electronic unit and
solenoid are disconnected
Light in the
sensor flashes
once when
user’s hands
are within the
sensor’s range
Unscrew solenoid, pull out the
plunger and the spring from
the solenoid and clean them.
Use scale remover material if
needed. When replacing the
plunger, please make sure that
the spring is in vertical position
Debris or scale in solenoid
Clean the orifice or replace
diaphragm
The central orifice in the diaphragm is plugged or
the diaphragm is torn
Reduce the supply water
pressure
The water supply pressure is higher than 8 bars
Shut off water supply and
unscrew one of the flexible
pipes in order to reduce the
pressure that blocks the product
The water supply pressure is under 8 bars and .5
yet the pressure in the faucet’s body is higher. This
situation could be caused by a sudden increase
in the water supply pressure that the back check
prevents from dropping, even after water supply
pressure drops under 8 bars
Clean the orifice or replace
diaphragm
Debris or scale in diaphragm
Sensor flashes
once when
user’s hands
are within the
sensor’s range
Water flow
from spout
does not
stop
Clean or eliminate case of
interference
**Sensor is dirty or covered
Light in the
sensor does not
flash once when
user’s hands
are within the
.sensor’s range
Decrease the range or eliminate
cause of reflection
Sensor is picking up reflections from the
.washbasin or another object
Remove, clean, re-install
Filter or aerator is clogged
Water flow
diminished
* ”Security Mode”: If the sensor is covered for more than 90 sec. The faucet will automatically shut off water flow.
To return to normal operation remove any blockage.
**In this case, the water will stop anyway after 90 seconds because of the security time.