background image

13

EN

SOLUTION

CAUSE

INDICATOR 

PROBLEM 

Replace battery

Low battery

 Sensor flashes

 continuously

 when user’s

 hands are within

 the sensor’s

range

 No water

 coming out

of the faucet

Increase the range

Range is too short

 Light in the

 sensor does not

 flash once when

    user’s hands

 are within the

sensor’s range

Decrease the range

Range is too long

 The battery must be replaced

 Battery is completely used up

*Unit is in Security Mode

 Eliminate cause of reflection

 Sensor is picking up reflections from the

washbasin or another object

 Connect the electronic unit

.connectors to the solenoid

 Connectors between the electronic unit and  

solenoid are disconnected

 Light in the 

 sensor flashes

 once when

 user’s hands

 are within the

sensor’s range

 Unscrew solenoid, pull out the

 plunger and the spring from

 the solenoid and clean them.

 Use scale remover material if

 needed. When replacing the

 plunger, please make sure that

 the spring is in vertical position

Debris or scale in solenoid

 Clean the orifice or replace

 diaphragm

 The central orifice in the diaphragm is plugged or

the diaphragm is torn

 Reduce the supply water

pressure

The water supply pressure is higher than 8 bars

 Shut off water supply and

 unscrew one of the flexible

 pipes in order to reduce the

pressure that blocks the product

 The water supply pressure is under 8 bars and .5

 yet the pressure in the faucet’s body is higher. This

 situation could be caused by a sudden increase

 in the water supply pressure that the back check

 prevents from dropping, even after water supply

pressure drops under 8 bars

 Clean the orifice or replace

 diaphragm

Debris or scale in diaphragm

 Sensor flashes

 once when

 user’s hands

 are within the

 sensor’s range

 Water flow

 from spout

 does not

stop

 Clean or eliminate case of

interference

**Sensor is dirty or covered

 Light in the

 sensor does not

 flash once when

 user’s hands

 are within the

.sensor’s range

 Decrease the range or eliminate

 cause of reflection

 Sensor is picking up reflections from the

.washbasin or another object

Remove, clean, re-install

Filter or aerator is clogged

 Water flow

diminished

* ”Security Mode”: If the sensor is covered for more than 90 sec. The faucet will automatically shut off water flow.
To return to normal operation remove any blockage.
**In this case, the water will stop anyway after 90 seconds because of the security time.

Summary of Contents for 8120B

Page 1: ...Ref 8120B 8120TB ...

Page 2: ...he installation and connection instructions are not followed theproduct warrantywill bevoid Avant d installer votre nouveau robinet il est impératif que vous nettoyiez l installation pour supprimer les impuretés qui s accumulent dans le système et qui pourraient endommager le produit Nous vous recommandons d installer des filtres dans les tuyaux d alimentation Retirez toutes les pièces de l emball...

Page 3: ...le Distancia min sensor 40 mm Distancia max sensor 170 mm Tiempo seguridad 90 s Temp Agua caliente Max 70 C Technische Merkmale Stromversorgung 9V Bat oder9V Trafo Dualpower Empfohlener Druck 0 5 8 0 bar Voreingestellter Sensorbereich Selbstjustierend Minimaler Sensorbereich 40 mm Maximaler Sensorbereich 170 mm Sicherheitszeit 90 sek Temp Heißwasser Max 70 C Caractéristiques techniques Source d al...

Page 4: ... antes de la instalación del grifo Batteries not included place in the battery box before installing the faucet Piles non fournies Installez les dans le compartiment de piles avant d installer le robinet DieBatterien nicht eingeschlossen vorEinbau desWasserhahnsindasBatteriefacheinlegen ...

Page 5: ...5 Ø10 G 1 2 ...

Page 6: ...6 1 2 3 4 ...

Page 7: ...7 5 6 R e m o ve O N L Y b e fo re co n n e ct in g th e p o w e r so u rc e 8 7 ...

Page 8: ... w e r s o u rc e R e m o v e O N L Y b e f o r e c o n n e c t i n g t h e p o w e r s o u r c e 12 11 NO REMOVE NO RETIRAR NO PAS RETIRER NICHT ENTFERNEN RECOMENDADA CAJA DE PROTECCIÓN RECOMMENDED PROTECTION BOX BOÎTE DE PROTECTION RECOMMANDÉE EMPFOHLENER SCHUTZKASTEN 10 ...

Page 9: ...ON INCLUSE NICHT ENTHALTEN RECOMENDADA CAJA DE PROTECCIÓN RECOMMENDED PROTECTION BOX BOÎTE DE PROTECTION RECOMMANDÉE EMPFOHLENER SCHUTZKASTEN NO SHINY NO BRILLANTE NON BRILLANTE NICHT GLÄNZEND NO OBJECTS NO OBJETOS PAS D OBJETS KEINE OBJEKTE ...

Page 10: ...10 16 17 19 B 18 B T ...

Page 11: ...at the ideal sensor range was set ant the product is ready for use Pour signaler que l autoréglage s est effectué un voyant rouge du capteur clignotera sans arrêt Le robinet à solé noïde s ouvrira et se fermera pendant 1 seconde pour signaler que la portée idéale du capteur a été établie et que le produit est prêt à être utilisé Als Hinweis darauf dass eine Selbst justierung durchgeführt wurde bli...

Page 12: ... émbolo asegúrese de que el resorte esté en posición vertical Suciedad en el solenoide Limpie el orificio o reemplace le diafragma El orificio central en el diafragma está obstruido o el diafragma está roto Reducir la presión de suministro de agua La presión del suministro de agua es más alta que 8 bares Cierre el suministro de agua y desenrosque una de las tuberías flexibles para reducir la presi...

Page 13: ...e diaphragm is torn Reduce the supply water pressure The water supply pressure is higher than 8 bars Shut off water supply and unscrew one of the flexible pipes in order to reduce the pressure that blocks the product The water supply pressure is under 8 bars and 5 yet the pressure in the faucet s body is higher This situation could be caused by a sudden increase in the water supply pressure that t...

Page 14: ...au est supérieure à 8 bars Coupez l alimentation en eau et dévissez un des tuyaux flexibles pour réduire la pression qui bloque le produit La pression d alimentation en eau est inférieure à 8 bars et malgré cela la pression dans le corps de robinet est majeure Cette situation pourrait être causée par une hausse soudaine de la pression d alimentation en eau et celle ci reste figée même lorsque la p...

Page 15: ...rgungsdruck verringern Der Wasserversorgungsdruck ist höher als 8 bar Schließen Sie die Wasserzufuhr und schrauben Sie eine der flexiblen Rohrleitungen ab um den Druck zu verringern der das Produkt blockiert Der Wasserversorgungsdruck liegt unter 8 bar der Druck im Armaturengehäuse ist jedoch höher Diese Situation könnte durch einen plötzlichen Anstieg des Wasserversorgungsdrucks verursacht werden...

Page 16: ...PKIS0047 00 1 2 1 2 3 MANTENIMIENTO MAINTENANCE MAINTENANCE WARTUNG ...