SYMPTOM 

POSSIBLE PROBLEMS   SERVICE

Preparing Tool for Operation—Battery/Charger Problems 

— Battery Cell does not    — Inoperative indicator    — Try Battery Cell in tool after 3 hours  

  appear to accept  

  lights on charger 

  on charge cycle. If tool LED is 

  charge. Green charger     

  green, charger lights are not 

  light does not come on     

  working properly. Replace charger, 

   

   

  or monitor charging time to ensure  

   

   

  Battery Cell has adequate time for  

   

   

  recharging. It’s normal for Battery  

  

  

 to feel warm after properly charging. 

   

— Battery Cell damaged    — Replace Battery Cell 

   

  or cycle life exhausted

   

— Damaged charger 

— Discontinue use immediately and  

  

  

 unplug from power source. Replace  

   

   

  charger and tag or dispose of  

   

   

  charger to prevent accidental  

  

  

 reuse or connection to power source.

— Flashing lights on   

— Damaged Battery Cell  — Replace Battery 

  charger base unit 

— Battery Completely  

— Allow battery to charge for  

   

  Drained 

  5 minutes

Normal Stage of Operation 

— Fan does not run 

— Battery in off position  — Fully insert Battery

 

—tool LED is off

 

— Battery Cell is  

— Charge Battery Cell according to  

   

  not charged 

  Operating Manual.  

   

— Battery terminals or  

— Clean Battery Cell terminals.  

   

  battery contacts are 

  Battery Cell contacts as required. 

   

  oily, dirty, or corroded   

— Fan does not run,  

— Battery Cell is  

— Charge Battery Cell 

  or runs slower than 

  discharged 

  normal—tool LED is red
— Fan does not run,  

— Possible electronics 

— Remove, reinsert the Battery 

  tool LED flashes  

  error 

    Contact Authorized Ramset  

  red/green 

   

  Distributor Sales Representative 

   

   

  for service.

Pre-Combustion/Combustion Stage of Operation 

— Work Contacting   

 —Work Contacting  

— Remove and inspect Work Contact 

  Element does not  

  Element is bent, or 

  Element. Repair or replace Work  

  depress fully—tool  

  build-up of debris in 

  Contact Element as required. 

  does not operate  

  nose restricts operation  

   

— Tool is out of fasteners  — Add fastener strip

— Tool will not cycle 

— Fuel Cell is empty 

— Replace Fuel Cell 

  —fan runs, LED 

  is green 
   

— Spark does not occur.  — Contact Authorized Ramset  

   

   

  Distributor Sales Representative  

   

   

  for service.  

Summary of Contents for TF1200

Page 1: ...SET TF1200 TOOL SYSTEM OPERATOR S SAFETY OPERATING INSTRUCTION MANUAL DANGER READ AND OBEY ALL SAFETY AND OPERATING INSTRUCTIONS BEFORE OPERATING TOOL GAS POWERED LOW VELOCITY PISTON TYPE FASTENING TO...

Page 2: ...rge refill or recycle fuel cells Never operate the TF1200 tool if flammable or explosive materials are nearby Just as no one can merely read a book about driving an automobile and then hope to drive o...

Page 3: ...ability of the base material can result in serious injury to the eyes or other body parts Center Punch Test ALWAYS WEAR SAFETY GOGGLES WHEN PERFORMING THIS TEST 1 Always check the material being faste...

Page 4: ...to fail or fasteners to fly free Fastening to Concrete Block or to Masonry Walls Take care to observe a 3 edge distance to avoid cracking the block and over penetration of the fastener to avoid a los...

Page 5: ...Never place your hand or any other body part over the fastener loading end of the tool Never carry the tool with your finger on the trigger Never leave the tool unattended or allow anyone to operate i...

Page 6: ...ng our environment and conserving our natural resources CHARGING INSTRUCTIONS 1 Connect the round plug of the wall mount unit to the front of the charger base and plug the wall mount unit into any 120...

Page 7: ...s powered If the light flashes red the battery requires charging If the light is solid green and the fan is running the tool is ready to take the next shot If the light is solid red and the fan is not...

Page 8: ...ueezes the inner fuel container much as you squeeze a tube of toothpaste This squeezing action ensures that all the fuel is used and that the TF1200 tool can operate in any position Because of this co...

Page 9: ...embly and pushing down until the Actuator Cover snaps into position OUTDOOR WEATHER AND THE TF1200 TOOL Use the TF1200 tool outdoors in clear weather when the Tool Fuel Cell and Battery are between 20...

Page 10: ...n strip 6 Place the tool in the spot where you want to make the fastening 7 With the tool in position and perpen dicular to the work surface press down on the tool 8 Note that the fan motor is running...

Page 11: ...rained 5 minutes Normal Stage of Operation Fan does not run Battery in off position Fully insert Battery tool LED is off Battery Cell is Charge Battery Cell according to not charged Operating Manual B...

Page 12: ...g Manual Use safe cleaning solution to remove stubborn debris Tool sleeve is dirty Clean tool Returning Purging Stage of Operation Tool operated and Built up dirt and Remove debris from Nose bore drov...

Page 13: ...places This warranty does not apply to part replacement required due to normal wear This warranty is void as to any tool which has been subjected to misuse abuse accidental or intentional damage use w...

Page 14: ...CENTER VISIT OUR WEB SITE AT WWW RAMSET COM OR CALL 800 241 5640 Concrete Fastening Systems Glendale Heights IL 60139 800 RAMSET6 1 800 726 7386 www ramset com Buy with Confidence Buy From Your Autho...