INSTALLATION & REPAIR GUIDE
Split Wall-Mounted air conditioner
STEP 1
*
Remove two screws on the maintance plate with
a screwdriver and take off the plate,then remove the
dust caps on both indoor male coupler and outdoor
female coupler,See Fig.9.
STEP 2
*
Press the projecting section of outdoor female
coupler backward with a little force by the thumb to
make inner hooks open, and then you can easily take
out the outdoor valve for gas leaking by the other
hand,See Fig.10.
STEP 3
*
In the same way,press the projecting section
backward,then connect the indoor male coupler to
the outdoor female coupler,See Fig.11.
STEP 4
*
Close the key lever of indoor male coupler to the
horizontal position,then indoor and outdoor refrigerant
will be circulating,and now you can obvioulsy hear the
sound of inner air flowing ,See Fig.12.
STEP 5
*
Connect the outdoor quick cable coupler with
indoor quick cable coupler,See Fig.13.
STEP 6
*
Finally,Re-install the mainteance plate back into its
place,See Fig.14.
As for the outdoor valve for gas leaking and the dust
caps,you can preserve them for future possible use on
the removal of your air conditioner.
*
If you purchase the machine for Whole-Unit type quick coupler model,please adopt the
following pipeplines connection procedures:
*
Pipelines connection for Whole-Unit type quick coupler model
*
Key lever
Indoor male coupler
Outdoor female coupler
Projecting section
Outdoor Valve for gas leaking
Outdoor female coupler
(With movable sheath)
Screw
Dust Cap
Outdoor Valve for gas
leaking(rear end)
7
Fig.9
Fig.10
Fig.11
Fig.12