O
peratOr
’
s
M
anual
RAMTEQ
®
14275 northwest freeway
houston, tX 77040
phone: 713.983.6000
faX: 713.983.6405
300-00002-01 11/05
p
age
ElEcTROdE sETTInGs
Inspection of all wires, spring
contacts and electrodes should
be done periodically.
OIl buRnER AIR bAnd AdjusTMEnT
RAMTEQ
®
sets oil burners at sea level. Air bands may need adjustment at higher elevations to offer
enhanced performance of the burner and extended life of the machine.
Adjustment of burner is done with pump motor and thermostat
set to maximum. Loosen locking screw on air band, then close
band until black smoke vents up exhaust vent. Take careful note
of air band position when black smoke is first noticed. Slowly
open air band until white smoke vents, then turn air band halfway
back to where black smoke was first noted. Tighten air band
locking screw. when properly set, the unit should NOT have either
"black" smoke or "white" smoke during operation.
IF blAcK OR WhITE sMOKE vEnTs FROM EXhAusT
PORT uPOn sTARTInG EQuIPMEnT, dIscOnTInuE usE
And AdjusT AIR bAnds bEFORE REsTARTInG.
�
WARNING
Maintenance Instructions
All RAMTEQ machines have the unloader
correctly set at the the factory. Setting an
unloader is a difficult job without the proper
equipment and training. Should the need arise
to change the unloader settings, please contact
your local distributor.
unlOAdER AdjusTMEnT
chAnGInG ThE unlOAdER sETTInGs WIThOuT ThE PROPER
EQuIPMEnT And TRAInInG MAy REsulT In nOn-WARRAnTy
dAMAGE TO ThE PuMP.
�
WARNING
Sutner
Unloader