Syntax
:
vldo
vldo on | off
Description
:
Displays and controls the power generator associated with port 5. The power generator
is a 5V overload protected generator capable of up to 50mA loads depending on duty
cycle. This generator is used for providing permanent power to special devices such as
rain gauges.
The
vldo
syntax displays current state of generator (on or off).
The
vldo
on/off
syntax turns the generator on or off respectively.
VP6
Syntax
:
vp6
vp6 on | off
Description
:
Displays and controls the power generator associated with port 6 (RS232/485). The
power generator is a 9V overload protected generator capable of 0.25A-1A loads
depending on duty cycle
The
vp6
syntax displays current state of generator (on or off).
The
vp6
on/off
syntax turns the generator on or off respectively.
VREF
Syntax
:
vref
vref on | off
Description
:
Displays and controls the high precision dual reference voltage generator associated
with sensor ports 1 through 4. This reference generator generates 5V with 0.15%
accuracy while delivering up to 10mA. A maximum current of 100mA can be delivered,
but with degrading precision.
The
vref
syntax displays current state of generator (on or off).
The
vref on/off
syntax turns the generator on or off respectively.
28 © Ranch Systems LLC, 2005-2011. All Rights Reserved. Reproduction without permission from Ranch Systems is prohibited.