60
12. STOPPING THE MACHINE
A - Temporary stop
L
&DUU\RXWFOHDQLQJDQGPDLQWHQDQFHRSHUDWLRQV
L
Wind up the cable and fasten it to the machine
ZLWKVWLFN\WDSH
L
&RYHUWKHPDFKLQHDQGSODFHLWLQDGU\URRP'R
not leave it exposed to atmospheric agents and
GRQRWDOORZLWWREHWRXFKHGE\FKLOGUHQRUXQLIW
persons.
To disconnect from the main power supply, consult
qualified personnel.
B - Definitive stop
L
%HVLGHVFDUU\LQJRXWWKHRSHUDWLRQVQHFHVVDU\IRU
DWHPSRUDU\VWRSFXWRIIWKHFDEOHSDFNWKHPD
-
FKLQHLQFDUGERDUGSRO\VW\UHQHRURWKHUSDFNLQJ
PDWHULDODQGFRQVLJQLWWR¿UPVDXWKRUL]HGIRULWV
disposal or to second-hand goods dealers.
13. PROBLEMS AND REMEDIES
Check operations to be carried out by the
user with the plug disconnected.
For any type of problem or inconvenience
not specifically indicated, disconnect the
plug and contact our service centre without
attempting any direct repairs.
A) The machine does not start:
- check that the plug is connected;
- In case of power failure wait for the power to return
and check if the earth leakage protection circuit
breaker or the main switch is on;
- check the condition of the plug and the supply
FDEOHLIGDPDJHGKDYHWKHPUHSODFHGE\TXDOL¿HG
personnel.
B) There is water under the machine:
- check that the drainage tray is not obstructed.
C) Slow dispensing:
- check that the filters and delivery heads are
clean;
FKHFNWKDWWKHFRIIHHLVQRWWRR¿QHO\JURXQG
',UUHJXODUVWHDPGHOLYHU\
- check that the nozzles are not obstructed.
11.3.1. Renewal of water in the boiler
(Fig.12)
7REHFDUULHGRXWRQO\E\TXDOL¿HGSHUVRQQHO
L
Turn off the machine and wait for the pressure in
the boiler to diminish (gauge needl on “0”).
L
Remove the cup-holder grid.
L
,QVHUWDUXEEHUKRVHLQWRWKHKRVHHQG¿WWLQJ
L
/RRVHQWKHKRVHHQG¿WWLQJ
L
$OORZWKHZDWHUWRÀRZRXWFRPSOHWHO\WKHQFORVH
WKH¿WWLQJDQGUHPRYHWKHUXEEHUKRVH
L
5H¿OOWKHERLOHUSDUDJUDSK
11.3.2. Regeneration
Softener DP2 - DP4
Regenerate the water softener within the time-limi-
ts specified for the softener as follows:
DP2
QUUHJHQHUDWLRQSHUPRQWKIRUFRIIHHVGD\
nr.2 regenerations per month (once a fortnight) for
FRIIHHVGD\
DP4
QUUHJHQHUDWLRQSHUPRQWKIRUFRIIHHVGD\
nr.2 regenerations per month (once a fortnight) for
FRIIHHVGD\
This table has been drawn up according to a water
hardness of 25 degress calculated on the French
scale.
See the documentation included with the softener
for the instructions for use.
Model S1 TANK
(Fig.13)
Operation to be carried out when the machi-
ne is off and cold and with the plug discon-
nected.
To be effected after the consumption of approx.15
litres of water (average hardness calculated as 35
degress on the French scale) or at least once a
month.
L
Prepare a solution in a glass of water adding three
WHDVSRRQVRI¿QHVDOWWKHVDOWPXVWEHSURSHUO\
dissolved).
L
Drain the water-tank, see point 10.2.
L
Slide the softener 1 (Fig.13) off the rubber tubing
2 and turn it over.
L
3RXUWKHVROXWLRQWKURXJKWKH¿OWHUDQGWKHUHVLQ
OHWWLQJLWÀRZGRZQIUHHO\
L
Wait about 5 minutes, then hold the softener un-
der a tap and rinse it with water. When the water
FRPLQJRXWRIWKHVRIWHQHULVQRORQJHUVDOW\WKH
UHVLQVDUHUHJHQHUDWHGDQGWKHVRIWHQHULVUHDG\
for use once again.
L
Put the softener back on the rubber tube and
UHSODFHLWKRUL]RQWDOO\RQWKHERWWRPRIWKHWDQN
L
On completion of this operation, the machine can
EHVWDUWHGXSDJDLQE\UHSHDWLQJWKHSURFHGXUH
described in paragraph 7.3.
Summary of Contents for EPOCA E
Page 4: ......
Page 6: ......
Page 8: ...8 1 2 3 4 5 6 8 7 9 10 mod S1 Fig 3 a 1 2 3 4 5 6 8 7 9 10 mod E1 Fig 3...
Page 9: ...9 Fig 4 Fig 5 4 L o v a t o L 2 3 8 G 1 30mm 1 2 3 4 5 6 8 7 9 10 12 mod S1 TANK Fig 3 b...
Page 10: ...10 4 mod S1 TANK 3 A B C D E 6 5 7 mod E1 S1 mod S1 TANK 1 2 2 8 8 9 1 Fig 6...
Page 11: ...11 1 2 A B C Fig 7 Fig 8 Fig 9 Fig 10 Fig 11...
Page 12: ...12 1 2 Fig 12 B C 2 1 Fig 13...
Page 35: ......