Unit Installation – con’t.
6. Carefully lift unit and lower unit onto the wall mounting bracket making
sure the unit mounting bracket is securely in the wall mount bracket.
7. Assure unit is level. Shimming may be required so unit is tilting at top or
bottom.
8. Plug in unit to appropriate power supply.
9. Allow unit time to cool down to temperature. Typical operating
temperatures are 34°F to 41°F.
10. Refer to the front of this manual for serial number location. Please
record this information in your manual on page 3 now. It will be
necessary when ordering replacement parts or requesting warranty
service.
11. Confirm that the unit is holding temperature. Set control to desired
temperature for your particular ambient and altitude.
NOTE: FAILURE TO FOLLOW INSTALLATION GUIDELINES AND
RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.
ELECTRICAL SUPPLY:
The wiring should be done by a qualified electrician in
accordance with local electrical codes. A properly wired and grounded outlet will
assure proper operation. Please consult the data tag attached to the compressor
to ascertain the correct electrical requirements. Supply voltage and amperage
requirements are located on the serial number tag located inside the mechanical
housing.
NOTE: it is important that your unit has its own dedicated line. Condensing
units are designed to operate with a voltage fluctuation of plus or minus 10%
of the voltage indicated on the unit data tag. Burn out of a condensing unit
due to exceeding voltage limits will void the warranty.