Trouble Shooting Guide (cont.)
Moisture around door
or frame
1.
Breaker strip faulty
2.
Frame heater faulty
3.
Temperature control set too low
1.
Inspect strips
2.
Call for service at 888-944-7636
3.
Adjust control to raise setting
Ice in drain pain or
water in bottom of unit
or floor
1.
Drain tube clogged
2.
Unit not level
1.
Clean drain
2.
Adjust leveling feet
CLEANING CONDENSOR COIL: An
accumulation of dirt and dust prevents the
condenser coil from removing, making your
unit cool poorly, run constantly, or even stop
completely if the compressor overheats.
Clean coil using a vacuum cleaner with
wand attachment. If the coil is greasy, wash
it with a solution of warm water the mild
detergent using a bristle brush. Take care
not to drip water onto other parts of the
condensing unit.
CLEANING DRAIN AND DRAIN PAN: Clean the
drain using an oven baster to force a solution of hot
water and baking soda or bleach into the drain opening.
To clear a stubborn clog, insert a length of 1/4" round
plastic tubing into the drain and push it gently through
to the drain pan; pull back out. Wash the drain pan
regularly with a solution of warm water and baking
soda.