OM-WORK TOP/UNDERCOUNTER SERIES 9
Operation
CHANGE FROM
º
F /
º
C :
1. Press the up/down buttons simultaneously for 5 seconds to access the menu.
2. Password is requested.
Password is 000.
3. Press the bottom left button to OK the password.
4. Using the up/down buttons, navigate to the “diS” level. Press the bottom left button
to OK the selection.
5. Using the up/down buttons, navigate to the “CFu” level. Press the bottom left button
to OK the selection.
a. “-F” designates Fahrenheit.
b. “-C” designates Celsius.
6. Press the top left button repeatedly to return to exit and return to the home screen.
DRAWER / DOOR ALARM:
Acknowledging Alarms – Visual Display Only
1. After 2 minutes the display will flash the alarm message “dor”
2. Press any button to acknowledge alarm
DRAWER / DOOR ALARM:
Door Alarm Activation – If audible alarm is wanted
1. Press the up/down buttons simultaneously for 5 seconds to access the menu.
2. Password is requested.
Password is 000.
3. Press the bottom left button to OK the password.
4. Using the up/down buttons, navigate to the “ALA” level. Press the bottom left button
to OK the selection.
5. Using the up/down buttons, navigate to the “Abd” level. Press the bottom left button
to OK the selection.
a. “0” Disables the alarm.
b. Any other number is the number of minutes before the buzzer sounds after the
drawer is opened.
6. Press the top left button repeatedly to return to exit and return to the home screen.
Summary of Contents for 9404F-290
Page 5: ...OM WORK TOP UNDERCOUNTER SERIES 5 EXTERIOR OF UNIT NEAR EXPOSED REFRIGERANT TUBING Labeling...
Page 18: ...18 OM WORK TOP UNDERCOUNTER SERIES Electrical Schematic...
Page 19: ...OM WORK TOP UNDERCOUNTER SERIES 19 Electrical Schematic...
Page 20: ...20 OM WORK TOP UNDERCOUNTER SERIES Electrical Schematic...
Page 21: ...OM WORK TOP UNDERCOUNTER SERIES 21 Electrical Schematic...
Page 22: ...22 OM WORK TOP UNDERCOUNTER SERIES Electrical Schematic...
Page 55: ......