Enclosed Base
No. of
No. of
120V 208V
240V Ship
Models L D H Wells
Elements KW Amps* NEMA KW Amps* NEMA KW Amps* NEMA
Wt.
RAN HTD-2 30" 27" 35" 2
2
2.2 18.4 5-30P 2.2 10.6 6-15P 2.2 9.2 6-15P
175
RAN HTD-3 48" 27" 35" 3
3
3.3 27.6 5-50P 3.3 15.9 6-20P 3.3 13.8 6-20P
215
RAN HTD-4 60" 27" 35" 4
4
4.4 36.8 5-50P 4.4 21.2 6-30P 4.4 18.4 6-30P
260
RAN HTD-5 72" 27" 35" 5
5
5.5 46 N/A 5.5 27.5 6-50P 5.5 23.0 6-30P
325
RAN HTD-6 86" 27" 35" 6
6
N/A N/A N/A 6.6 31.7 6-50P 6.6 27.5 6-50P
390
Dry Storage Base
RAN HTD-2S 30" 27" 35" 2
2
2.2 18.4 5-30P 2.2 10.6 6-15P 2.2 9.2 6-15P
175
RAN HTD-3S 48" 27" 35" 3
3
3.3 27.6 5-50P 3.3 15.9 6-20P 3.3 13.8 6-20P
215
RAN HTD-4S 60" 27" 35" 4
4
4.4 36.8 5-50P 4.4 21.2 6-30P 4.4 18.4 6-30P
260
RAN HTD-5S 72" 27" 35" 5
5
5.5 46 N/A 5.5 27.5 6-50P 5.5 23.0 6-30P
325
RAN HTD-6S 86" 27" 35" 6
6
N/A N/A N/A 6.6 31.7 6-50P 6.6 27.5 6-50P
390
Heated Storage Base
RAN HTD-2B 30" 27" 35" 2
2
3.3 27.6 5-50P 3.03 14.6 6-20P 3.3 13.8 6-15P
175
RAN HTD-3B 48" 27" 35" 3
3
4.4 36.8 5-50P 4.125 19.8 6-30P 4.4 18.4 6-30P
215
RAN HTD-4B 60" 27" 35" 4
4
5.5 46 N/A 5.225 25.1 6-50P 5.5 23 6-30P
260
RAN HTD-5B 72" 27" 35" 5
5
N/A N/A N/A 6.325 30.4 6-50P 6.6 27.5 6-50P
325
RAN HTD-6B 86" 27" 35" 6
6
N/A N/A N/A 7.6 36.5 6-50P 7.6 31.7 6-50P
390
* Note: Amperage for base unit only. Any accessory heat lamp or display illumination loads must be added to the total amperage.
COMMON DATA FOR HTD SERIES (INCLUDES THE STANDARD HTD SERIES AND THE “S” STORAGE BASE SERIES)
Top Work No. of 120V Operation 208V Operation
240V Ship
Models L D H 12x20 Wells KW/well Amps* NEMA KW/well Amps* NEMA KW/well Amps* NEMA Wt.
RANFG HTD-2 30" 30" 35" 2
2.2 18.4 5-30P 2.2 10.6 6-15P 2.2 9.2 6-15P 175
RANFG HTD-3(S) 48" 30" 35" 3
3.3 27.6 5-50P 3.3 15.9 6-20P 3.3 13.8 6-20P 225
RANFG HTD-4(S) 60" 30" 35" 4
4.4 36.8 5-50P 4.4 21.2 6-30P 4.4 18.4 6-30P 275
RANFG HTD-5(S) 72" 30" 35" 5
N/A N/A N/A 5.5 27.4 6-50P 5.5 23.0 6-30P 325
RANFG HTD-6(S) 86" 30" 35" 6
N/A N/A N/A 6.6 31.7 6-50P 6.6 27.5 6-50P 375
STORAGE SHELF INFORMATION FOR HTD ”S” SERIES
2-well not available with storage shelf (too small)
Models L (A) W(B) H(C) Ship Wt.
RANFG HTD-2S 48" 23" 14.5" 250
RANFG HTD-3S 60" 35" 14.5" 300
RANFG HTD-4S 72" 47" 14.5" 350
RANFG HTD-5S 86" 61" 14.5" 400
HTD “B” HEATED BASE SERIES
L Top Work No. of No. of No. of 120V 208V 240V
Models (A) D H 12x20 12x20 18x26 Operation Operation Operation
wells tops wells base wells base KW/well Amps* NEMA KW/well Amps* NEMA Ship Wt.
RANFG HTD-4B 60" 30" 35" 4
4
3 N/A 5.225 25.4 6-50P 5.5 23 6-30P 400
RANFG HTD-6B 86" 30" 35" 6
8
8 N/A 7.425 36 6-50P 7.7 32 6-50P 500
*Amp loads for base unit with light option-adding any Heat lamps or incandescent light options will change total load and/or
number of electrical cords/connections (consult factory for clarification).
*14G models available with 14Gauge SS tops
19
A. RECEIVING SHIPMENT
B. ELECTRICAL SUPPLY
Upon arrival, examine the exterior of the shipping crate for signs of abuse. It is advisable
that the shipping crate be partially removed, in order to examine the cabinet for any pos-
sible concealed damages which might have occurred during shipment. If no damages are
evident, replace the crate in order to protect the unit during storage and local delivery. If
the unit is damaged, it should be noted on the delivery slip or bill of lading and signed to
that effect. A claim must be filed immediately against the carrier indicating the extent and
estimated cost of damage occurred.
The wiring should be done by a qualified electrician in accordance with local electrical
codes. a properly wired, and grounded outlet will assure proper operation. Please consult
the data plate attached to the compressor to ascertain the correct electrical requirements.
Supply voltage and amperage requirements are located on the serial number tag.
NOTE: It is important to verify that the correct voltage. Supplying the incorrect
voltage can detrimentally affect the unit and thereby void its warranty.
NOTE: It is important that your unit have its own dedicated line; hot food holding
units are designed to operate with a voltage fluctuation of plus or minus 10% of the
voltage indicated on the unit data plate. Burnout of electrical components due to
exceeding voltage limits will void the warranty.
NOTE: Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to this manual for assistance or consult a
qualified installer, service agency, or dealer.
UNIT INSTALLATION
randell.com