Physiolaser 

olympic 500

 

 

Version 1.4  June 2007 

 

   

 

 

 

36

 

International plugs  

As an optional accessory you can use various interchangeable plugs corresponding to 
the international electric systems (Australia, USA, England, Europe). 

 

New installation of the software, update 

The front panel provides an opening for a memory card (SD format). By means of the 
RJ-memory card you can install the main software or update the device. 

1.  Insert SD card  
2.  Turn the key to ON  
3.  Follow the instructions on the screen  

 

Error messages 

The following error messages can occur in case of internal demage or failure. 
 

Device 

Error message 

Reason 

What to do 

Main Unit 

"Insert SD-Card" 

No SD-Card detected 
(SD-Card may be defective) 

Insert SD-Card

 

 

 

 

Single Probe  "Laser 1 defect !" 

 

Laserdiode defective 

Press 
"Start/Stop" 

 

"Laser 1 Overload!" 
 

Laserdiode 1 Overcurrent 

Press 
"Start/Stop" 

 

 

 

 

Cluster 
Probe: 

"Laser x defect !" 
 

Defekte Diode,  
x = number of laserdiode 

Press 
"Start/Stop" 

 

"Laser x Overload" 
"A:nnn V:mmm " 
 

Laser Overcurrent, x=number,  
nnn and mmm are values 
measured by the system 

Press 
"Start/Stop" 

 

 

 

 

All systems 

"E2prom Corrupted!" 
 

Memory defective 

" Contact 
Service " 

 
If an error message occurs, press „Start/Stop“. 
If the error occures again after adjustment, contact your supplier or the RJ service 
(service@rj-laser.com). 
 

Summary of Contents for Physiolaser olympic 500

Page 1: ...Physiolaser olympic 500 Version 1 4 June 2007 1 Physiolaser olympic 500 Instructions for Veterinary Use ...

Page 2: ... device with the Key switch 15 Button functions on the display yellow color shows active function 16 Pre settings default setting 21 Starting operation 23 Operational modes 25 Before starting the therapy mode 25 Selecting the settings for the laser probe Power Energy Time 26 Pilot beam laser control LED on the probes 28 Acoustic control 28 Laser Test 29 NOGIER BAHR program 29 REININGER program 30 ...

Page 3: ...m Certified according to EN ISO 13485 2003 Exclusion of liability The Physiolaser olympic should only be used for the purpose described in these operating instructions The manufacturer will not be liable for any damage or injuries resulting from usage not contained in these operating instructions The manufacturer reserves the right to make modifications in keeping with technological advances Physi...

Page 4: ... olympic are proven through several years of intensive research and offer an exact supply of photon energy to the body The Physiolaser olympic meets the requirements of the following International standards EN 60601 1 1996 Safety of Medical Electrical Equipment EN 60601 2 22 1996 Safety of Diagnostic Therapeutic Lasers EN 60825 1 2003 Safety of Laser Devices DIN EN 60601 1 2 Electro magnetic compa...

Page 5: ... operator must be able to name a laser safety representative Treatment room The laser may only be operated in closed rooms The treatment room in which laser therapy is performed must meet the requirements of the Accident Prevention Regulation BGV 11 Laser radiation Attach a warning sign to all inputs in accordance with DIN IEC 76 CO 6 Reflecting objects mirrors and chrome parts must be removed Saf...

Page 6: ...3 42 EWG IIa Current supply Charger Model FRIWO FW7555M 08 Weight 2 kg Dimensions L x B x H 25 x 10 x 15 cm Operating conditions Room temperature 10 C to 40 C Relative humidity 30 to 75 Atmospheric pressure 700 hPa to 1060 hPa Transport and storage Room temperature 20 C to 40 C Relative humidity 30 to 75 Atmospheric pressure 700 hPa to 1060 hPa Content of delivery incl Current supply charger safet...

Page 7: ...le cm2 and proceed on the following treatment day at the same energy if improved or increase until healing is performed You can modify the treatment parameters according to scientific research e g recommended average dosage of 4 Joule cm2 or according to the reactions at any time Please refer to the training manual to obtain further information regarding the applications Indications Acupuncture St...

Page 8: ...ous test are performed in order to insure that the device is operating within the tolerances that the device was originally designed This annual inspection calibration must be submitted to an authorized facility Repairs or maintenance performed by an unauthorized facility or personnel will void your warranty Inclusive with your device will be shipping labels and instructions for deliver to the rep...

Page 9: ...meets the requirements of 93 42 EEC for medical products Attention Observe the instructions in the manual for safe and effective usage of this device Symbol for the laser beam Warning for laser beam Explanatory Label Symbol International Visible and invisible laser radiation including the standard which was used for the classification of the laser Singel probe Multi cluster probe Labels according ...

Page 10: ...aser radiation including the standard which was used for the classification of the laser Right Label indicating technical data serial number and address of the manufacturer Aperture labels according to EN 60825 1 Front side on the cluster probe Laser aperture laser beam direction and explanatory label Rear Label indicating technical data as probe type serial number power pulse ...

Page 11: ...40 mW 4 x max 5 mW Continuous CW Continuous CW Continuous CW 0 10 0 09 0 04 0 140 rad 0 157 rad 0 155 rad 518 904 nm 12 x max 10 W Impulse 200 ns 0 05 0 190 rad Safety distance NOHD Distance at which the radiation intensity or the radiation is equivalent to the limiting value of the maximum permitted radiation of the cornea MZB For more information please refer to the device plate The controller o...

Page 12: ...requency main groups Nogier BAHR REININGER free frequencies therapy programmes Press Short rows long main groups Buttons on the cluster laser probe Laser Start Stop Press Short full power long reduced power Display Slot for the memory card LaserTest Sockets for the laser probe Socket for the diagnostic probe hand electrode Remote laser stop Key switch Emergency stop Display Current connected Scrol...

Page 13: ...uencies Cluster probes Universalsonde 4x5 mW 655 nm 4x40 mW 655 nm 4x55 mW 785 nm 12x10 W 904 nm Brush mit Fiberoptiken 4x5 mW 655 nm 4x40 mW 655 nm 4x55 mW 785 nm 12x10 W 904 nm Derma 4x5 mW 635 nm 6x45 mW 655 nm 2x55 mW 785 nm Kompakt 5x 30 W 904 nm Impuls 200 nsec ...

Page 14: ...onnected probe is recognized but not active Laser data yellow on Connected probe is recognized and active LED red on Main unit is connected with the power supply to the mains current 30 red flash accumulator will soon be empty please charge Probe LED red Flashes on 2 seconds during start procedure Laser is active Pilot LED red on Illuminates the area to be radiated distance 30 mm 2 seconds before ...

Page 15: ...e display will activate the functions Ready therapy mode frequency selection laser setting diagnosis Pre settings manufacturer s data version no Language setting Indicates the Stand by mode Frequency group Single frequency Battery indicator Stand by button Frequency row Frequency mix Laser settings Single and multi cluster probe ...

Page 16: ...by indicates the condition of the battery Lower buttons are corresponding with Stand by mode setting of Power Energy Time and probe selection Two probes connected data valid for the single probe yellow Frequency selection NOGIER Frequency B for the single probe Frequency mix Frequency selection NOGIER B C Here frequency B C for the single probe In order to mix follow the steps Select the first fre...

Page 17: ...00 Version 1 4 June 2007 17 Frequency selection BAHR1 Frequency 5 for the multi cluster probe Frequency selection BAHR2 Hysteria frequency for the multi cluster probe Frequency selection Chakra 1 8 acc to BAHR Sexual Chakra ...

Page 18: ... selection Chakra 9 15 acc to BAHR Protection Chakra Frequency selection Meridian 1 acc REININGER Small Intestine Frequency selection Meridian 2 acc REININGER Liver Frequency selection Reininger Reininger 1 RI 2 Reininger I to II have a similar display design ...

Page 19: ...iolaser olympic 500 Version 1 4 June 2007 19 Frequency selection Reininger Level 2 K HWP Frequency selection Reininger Anti Freq 2 Anti inflammation Frequency selection Reininger Viral Bacterial Anti viral ...

Page 20: ...ilable for the therapy programs Frequency selection Free Frequency Free Freq 6 F 6 Available are 10 memories each with 11 spaces Individual programming of frequency and name is possible please press the button Edit Selection of power energy time duty cycle and therapy beep Press one of the buttons to change the value Enter will store the value Therapy leads back to the main therapy menu ...

Page 21: ...for language Laser Tester and usage meter and information about the version number software updates manufacturer Setup menu with information of the manufacturer and options for Language Version Usage Meter IR Sensor Laser Test Software Stand by back to the Stand by menu Pre setting Language English Pre setting Version number ...

Page 22: ...mpic 500 Version 1 4 June 2007 22 Pre setting Usage meter with additional coding Pre setting Activation and changing the sensibility of the Laser Test on the front panel Pre setting Information about software updates ...

Page 23: ...ASER STOP To safeguard against unauthorized use the Physiolaser olympic is equipped with a removable safety plug Insert the safety plug in the socket on the front panel You can use thesafety plug in contact to a foot switch or a door contact Please ask your service for detailed instructions how to use the remote contact Usage of the EMERGENCY STOP The red EMERGENCY STOP button can be accidentally ...

Page 24: ...lly green the battery is sufficiently charged If turns to yellow and red please recharge the battery or use mains current supply In order to charge the battery attach the power supply into the socket of the mains supply and connect the plug with the socket at the back side of the Physiolaser olympic Please note that the battery can not be overcharged and the Physiolaser olympic can be used at any ...

Page 25: ... the Ready mode you can select frequencies modify the power settings and start the laser beam Laser Ready The laser is ready if the main therapy screen is displayed Start the laser by pressing button Start stop on the probe Pressing Stand by again will lead to the Stand by mode Power save The display indicates POWER SAVE Start of the Stand by mode via the Stand by button other buttons are not in u...

Page 26: ...on Therapy As soon as the settings are stored the laser can be started with the button Start Stop Release of the laser beam display after laser start 1 Press Ready the device steps to Ready mode 2 You can read the laser settings power energy time on the display 3 Press button Start Stop on the probe to release the laser according to the settings 4 Press button Start Stop shortly to release the las...

Page 27: ...03 12 500 02 14 Battery Laser power Expired therapy time Laser power indication 5 too low correct 5 too high When the time has expired the laser will shut off automatically countdown with indication of the remaining time In the therapy menu you will find the actual value of the time in the upper line of the display Display message for reduced power RAC diagnosis A 292 00 03 12 R 500 02 14 Power co...

Page 28: ... 904 impulse laser nm or 12 x cw mix With photon reflection foil With derma lens Brush type with fiber optic 5x30 W 904 nm Impulse laser Probe with single laser diode The laser beam and the pilot beams will meet after 30 mm two seconds before the laser starts The control LED on the front panel will glow thereafter continuously laser active Acoustic control During the release of the laser you will ...

Page 29: ...0 Hz Bahr 2 Pain 963 5 Hz Hysteria 1131 H Homeopathy 7708 Hz Anti allergy 1927 Hz Defence 699 Hz Yang Energy 637 Hz Yin Energy 1102 Hz Meridians Reininger Lu 824 Hz Li 553 Hz St 471 Hz MP 702 Hz He 497 Hz Si 791 Hz Bl 667 Hz Ki 611 Hz Ci 530 Hz 3H 732 Hz Gb 583 Hz Li 442 Hz Chakra Crown 232 Hz Third eye 573 Hz Throat 990 Hz Heart 1589 Hz Solar Plexus 2398 Hz Sacral 3123 Hz Basis 4032 Hz Shaman 8 2...

Page 30: ...ti Psyche 4221 Hz Vegetative 112 Hz Anti vegetative 3665 Hz Addiction 112 Hz Anti addiction 3305 Hz Carcinoma 108 Hz Anti Carcinoma 3534 Hz Pain 119 Hz Anti pain 3894 Hz Inflammation 128 Hz Anti inflammation 4189 Hz Allergie 3648 Hz Anti Allergy 933 Hz Tinnitus 125 Hz Anti Tinnitus 4090 Hz General 384 Hz Frequencies of levels Melatonin HP 1025 Hz VIP1 1808 Hz VIP2 3616 Hz TUP 7232 Hz GV CV 456 Hz ...

Page 31: ...ncies Select the free programable frequencies and change the frequency and the name by pressing the button Edit Free Frequency display 10 memories each providing 11 spaces for total 110 frequencies After the specific numbers are selected the frequency can be used for therapy ...

Page 32: ...chosomatic Block Focus Allergy Orthopädie Arthritis Arthrosis Fracture Muscles Tendons Ligaments Distorsion Trauma Edema Haematoma Lumbalgia Synovitis Pain Derma Acne Herpes Alopecia areata Alopecia difusa Itching Wound acute Wound chronic Scars Neuro dermitis Odema Regeneration Dental Arthrosis Post extractum Parodontitis Mucosa Bones Hypersensibilidad Edema Blockage Psyche Vet Continuous Wounds ...

Page 33: ...e to activate the diagnostic mode The diagnosis screen will appear With the buttons Sensibility you can select the sensitivity at 3 levels Llow standard high Each step the sensitivity doubles the sensitivity the level high offers 4 times as much sensitivity as level L Pressing the button Clear will reset the memory 255 back to 0 Pressing button Therapy will lead to Stand by ...

Page 34: ...panel of the Physiolaser olympic The patient must hold the hand electrode Point search Point searching is based on the fact that conductance differs along the surface of the skin in terms of distribution Keep in mind that the search procedure calls for a certain degree of practice and routine You will be looking for the point where the electrical conductance is either slightly less than that of ne...

Page 35: ...rcuit is complete for the diagnosis Charging the battery The green bar above the Stand by button will indicate the condition of the battery If the battery should be charged the color will turn to yellow and in case of red the device will shut off soon Please note that you can charge the Physiolaser olympic can be connected to the mains current constantly and the battery can be charged at any time ...

Page 36: ...or messages can occur in case of internal demage or failure Device Error message Reason What to do Main Unit Insert SD Card No SD Card detected SD Card may be defective Insert SD Card Single Probe Laser 1 defect Laserdiode defective Press Start Stop Laser 1 Overload Laserdiode 1 Overcurrent Press Start Stop Cluster Probe Laser x defect Defekte Diode x number of laserdiode Press Start Stop Laser x ...

Page 37: ...igh energy density and will keep the opening clean Attach screw the applicators onto the probe tip According to the area to be treated point or larger surface select the applicators The lens does not focus the beam it will protect the laser diode against damage or contamination during skin contact The applicators should be sterilized before and after the therapy Application Nr 5201 Dental applicat...

Page 38: ...s or an authorized service station Always ensure that operational and sufficiently charged batteries are used The interior of the Physiolaser olympic contains no elements or components which require servicing by the user Therefore there is no need to open the housing To meet the requirements of DIN VDE 0837 Radiation safety for laser devices the unit is to be tested and recalibrate after one year ...

Page 39: ...ectly connected to mains for the public supply which are also servicing buildings used for residential purposes Guidelines and manufacturer s declaration Electromagnetic immunity Immunity tests IEC 60601 Test level Conformity level Electromagnetic ambient conditions guidelines Discharge of static electricity ESD according to IEC 61000 4 2 6 kV Contact discharge 8 kV Air discharge conforms The floo...

Page 40: ...cation should be taken into consideration If the field strength measured in the place where the laser device is operated exceeds the above mentioned conformity level the laser device should be watched to proof its function in accordance to the requirements Unusual performance data may require additional measures for instance change of orientation or different location of the laser device b Above t...

Page 41: ...echnology Frohnacker 8 79297 Winden Germany Tel 49 7682 6558 Fax 49 7682 6640 service rj laser com www rj laser com Certified according to EN ISO 13485 2003 Distributed by H R Medics Limited Forge Cottage Ousden Newmarket Suffolk CB8 8TR Tel 44 0 1638 500825 Fax 44 0 1638 500825 info hrmedics co uk ...

Reviews: