R&M Materials Handling, Inc
STAGEMAKER® COMPACT Concert Hoist
Springfield, Ohio USA
SM5 Manual
: 800 955-9967
Revision 1
web:
www.rmhoist.com
08/14/02
RM-SM5-MAN-2001-1-ENG
1-2
General
Each complete electric chain hoist is load tested in accordance to ANSI B30.16 at the factory at
125% of nameplate rated capacity, and is usually shipped assembled, unless otherwise stated on
order inquiry.
All hoists are designed for the type of mounting specified by the purchaser. The adequacy of the
supporting members (monorail beams, trusses, hangers, supports, framing, etc.) is the responsibility
of the user and shall be determined by qualified personnel.
Prior to permanent or field installation, units shall be checked thoroughly by qualified personnel for
damage during shipment or handling at the job site. Particular attention shall be taken to make sure
that the load chain and other mechanical or electrical components have not been damaged through
improper handling.
Read the instructions contained in this manual and observe the warning tags attached before
installation is started.
Hoist Configuration
STAGEMAKER
®
COMPACT concert hoists are offered in five basic configurations, each with its
own control type and hoist features.
Ø
Configuration A
: Direct motor control without control voltage. Full line voltage controller
furnished separately.
Ø
Configuration B
: Magnetic controls including a control transformer for controls and controller.
Ø
Configuration B1
: Standard (upright) hoist mounting position only. PC Board controls
and pendant controller furnished on the hoist.
Ø
Configuration B2
: Inverted or standard hoist mounting position. PC Board controls
furnished on hoist and controller ordinarily furnished separately.
Ø
Configuration C
: Programmable controller in conjunction with PC Board controls. Controls
furnished on the hoist and controller furnished separately.
Ø
Configuration D
: Mandatory safety features are standard. PC Board controls furnished on the
hoist and controller furnished separately.
Ø
Configuration E
: Variable Frequency Drive (inverter). VFD furnished by others separate from
hoist.
PC Board controls utilize magnetic (low voltage) controls. PC Board controls for the SM5 concert
hoists consist of controls (contactor, transformer, etc.) that are soldered to a circuit board, which
provides most of the internal connections.
WARNING
Before installing the hoist, make certain that the main power switch
supplying power to the hoist is in the open position.