background image

Safety Instructions

R&S

®

QPS201

5

Getting Started 1179.3438.02 ─ 02

1

 

Safety Instructions

The R&S

 

QPS is manufactured according to the highest technical standards. To use

the scanner safely, follow the instructions provided here and throughout the product
documentation. Keep the documentation nearby and offer it to other users.

Use the scanner only as intended and within its performance limits. The limits are
described in the product documentation, such as the data sheet, manuals and this bro-
chure. If you are unsure about the appropriate use, contact the Rohde

 

&

 

Schwarz cus-

tomer service.

Using the scanner requires specialists or specially trained personnel. These users also
need sound knowledge of at least one of the languages in which the user interface and
the product documentation are available.

If any part of the product is damaged or broken, stop using the product. Never open
the casing of the scanner or its components. Only service personnel authorized by
Rohde

 

&

 

Schwarz are allowed to repair the product.

Lifting, carrying and installing the R&S

 

QPS

The R&S

 

QPS is heavy and can cause physical injuries when it falls or tips over.

Setup and installation must be done by trained staff. Make sure to install the R&S

 

QPS

exactly as described in the installation manual. During the installation, make sure that
the installation site is only accessible by people working on the installation.

Because of its weight, at least two strong people are required to move or install the
scanner. Lifting heavy items can cause structural and muscular injuries. You must use
the specially designed installation tool if you have to move or lift the scanner panels
(R&S

 

QPS-Z800, order no. 1333.5900.02). You must also use the installation tool to

install the scanner on the platform.

Using the installation tool can pinch your fingers, especially when you attach it to the
R&S

 

QPS and when you use the levers.

Loose ball-lock pins can cause the panels to fall over during transportation. Make sure
that the ball-lock pin is seated correctly whenever you use one.

If you have to move the pallet the R&S

 

QPS is delivered on, always use a forklift.

During transport, installation or repair, wear appropriate protective clothing that com-
plies with your local rules and regulations. If you are unsure of which equipment to use,
ask your safety inspector.

We recommend to wear:

Safety shoes with toe cap and ESD protection.

Protective gloves

ESD protected shoes and gloves also protect the hardware from being damaged.

Summary of Contents for 1333.5000K02

Page 1: ...R S QPS201 Quick Personnel Security Scanner Getting Started 1179343802 Version 02 ÝRV2 ...

Page 2: ...1671 München Germany Phone 49 89 41 29 0 Email info rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners 1179 3438 02 Version 02 R S QPS201 Throughout this manual products from Rohde Schwarz are indicated without the symbol and without the mo...

Page 3: ...Contents R S QPS201 3 Getting Started 1179 3438 02 02 Contents 1 Safety Instructions 5 2 Regulatory Information 8 3 Key Features 10 4 EMI Suppression 11 5 System Components 12 6 Preparing for Use 14 ...

Page 4: ...Contents R S QPS201 4 Getting Started 1179 3438 02 02 ...

Page 5: ...up and installation must be done by trained staff Make sure to install the R S QPS exactly as described in the installation manual During the installation make sure that the installation site is only accessible by people working on the installation Because of its weight at least two strong people are required to move or install the scanner Lifting heavy items can cause structural and muscular inju...

Page 6: ...able delivered with the R S QPS It complies with country specific safety requirements Only insert the plug into an approved grounded outlet For components that need an external AC adapter only use the one that is deliv ered with the components Only use intact cables and route them carefully so that they cannot be damaged Check the power cables regularly to ensure that they are undamaged If the vol...

Page 7: ...rsonal injury or even death Protective ground terminal Connect this terminal to a grounded external conductor or to protective ground This protects you against electric shock if an electric problem occurs Pinched fingers Indicates a potential risk of pinching your hands or fingers Protective clothing Indicates that you must wear protective clothing when you use the device to avoid physical injurie...

Page 8: ...érieur uniquement 2 2 Regulations for the USA Changes or modifications not expressly approved by the party responsible for compli ance could void the user s authority to operate the equipment The R S QPS is currently restricted to indoor operations as of October 2020 The R S QPS may only be operated on a non interference basis to existing and future services with frequency allocations in the 70 GH...

Page 9: ... 02 manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Regulations for the USA ...

Page 10: ... microwaves are of very low intensity The signal level is several orders of magnitude below the signal level of mobile phones Therefore the system presents no health hazards for the scanned persons A person is scanned front and back The data is analyzed and evaluated by an auto matic detection software algorithm After the evaluation the scanned person either is cleared or has to undergo further in...

Page 11: ...tromagnetic interference EMI may affect the measurement results To suppress generated electromagnetic interference EMI Use suitable shielded cables of high quality For example use double shielded LAN cables Always terminate open cable ends Note the EMC classification in the data sheet ...

Page 12: ... connected to each other The primary panel shows the silhouette of a person Otherwise both panels are the same A floorplate that provides a stable and even surface for the scanner A touchscreen monitor to control the scanner The touchscreen monitor is connec ted to the primary panel The images show the components of HW 3 50 The components of HW 3 30 are the same except for the connectors which are...

Page 13: ...QPS201 13 Getting Started 1179 3438 02 02 1 Secondary panel 2 Primary panel with printed avatar on the inside 3 Rear side of the panel facing outward 4 Front side of the panel facing inward 1 Floorplate 2 Touchscreen monitor ...

Page 14: ... metal detector LAN LAN LAN USB DisplayPort Power LAN Remote Power AC AC Secondary Panel Mandatory system components Optional system components LAN LAN Figure 6 1 Connection overview The overview shows the connections for HW 3 50 For HW 3 30 the touchscreen is connected to a wall outlet instead of the primary panel Otherwise the connections are the same for both hardware variants The connections f...

Page 15: ...rriers via USB for details see the installation manual Connecting the components to the power supply Connect all devices to the mains supply with the power cord that is part of the delivery For resolution stations you have several methods to supply them with power Connect them to the AC mains supply Connect them to an external PoE injector R S QPS Z113 If you are using this method connect all reso...

Page 16: ...ainst overcurrent Oth erwise the fuse can blow We recommend that you use a power cable that is rated for a 16 A included in the delivery and connect each panel to a separately protected power circuit at least 10 A If you cannot connect the panels to separate power circuits make sure that the system is protected By a fuse with at least 20 A in 200 V networks By a fuse with at least 16 A in 230 V ne...

Page 17: ...aving mode The R S QPS enters an energy saving mode when it is not used for a while Waking up from this mode takes a a few seconds A corresponding message is dis played on the operator touchscreen Turning off the system 1 On the touchscreen monitor enter the home menu 2 Select the Shut Down menu item The system shuts down 3 Turn off the mains power switch position 0 The panel is disconnected from ...

Reviews: