R&S FSMR
Analyzer - MEAS
1166.3363.12
4.16-33
E-2
CONT
MEAS
The
CONT MEAS
softkey starts collecting a new sequence of sample data
and calculating the APD or CCDF curve depending on the selected
measurement. The next measurement is started automatically as soon as the
indicated number of samples has been reached ("CONTinuous
MEASurement").
IEC/IEEE-bus command:
INIT:CONT ON;
INIT:IMM
SINGLE
MEAS
The
SINGLE MEAS
softkey starts collecting a new sequence of sample data
and calculating the APD or CCDF curve depending on the selected
measurement. At the beginning of the measurement previously obtained
measurement results are discarded.
IEC/IEEE-bus command:
INIT:CONT OFF;
INIT:IMM
Hint for usage of the marker functions with measurement of signal statistics:
With the signal statistic measurement level always is displayed on x-axis. Y-axis always is a normalized
value between 0 and 1. In contrary to use of marker in frequency or time domain marker is input in level
values and the output is in percentage values.
Example:
Measurement of CCDF of a IS95 BTS signal, level 0 dBm, frequency 800 MHz
[
PRESET
]
Switch on preset settings.
[
FREQ
:
CENTER
: 800 MHz]
Set center frequency to 800 MHz.
[
AMPT
: 10 dBm]
Set reference level to 10 dBm.
[
BW
: 3 MHz]
Set resolution bandwidth to 3 MHz (resolution bandwidth shall be wider
then signal bandwidth (1.25 MHz) in order to have the complete signal
within the resolution bandwidth).
[
MEAS
]
Call the menu for measurement functions.
[
SIGNAL STATISTIC
]
Call the menu for signal statistics measurement.
[
CCDF ON /OFF
]
Switch on measurement of the complementary cumulative distribution
function. The R&S FSMR switches to zero span mode. The power of
the signal and the CCDF is calculated for the number of samples
selected. With the CCDF function sample detector and video bandwidth
are set automatically.
[NO OF SAMPLES: 10000]
Set the number of measurement samples to 10000.
[SINGLE MEAS]
Start the measurement sequence. At the end the resulting trace will
display the CCDF for the measured 10000 samples.
Summary of Contents for FSMR
Page 1: ...R S FSMR Measuring Receiver Operating Manual Test Measurement Operating Manual 1313 9723 12 01...
Page 4: ......
Page 22: ......
Page 26: ...Contents Preparing for Operation R S FSMR 1155 5047 12 I 1 2 E 2 Fig 1 1 Front View...
Page 28: ...Front View R S FSMR 1166 3363 12 1 2 E 2 Fig 1 1 Front View...
Page 30: ...Front View R S FSMR 1166 3363 12 1 4 E 2 Fig 1 1 Front View...
Page 32: ...Front View R S FSMR 1166 3363 12 1 6 E 2 Fig 1 1 Front View...
Page 34: ...Front View R S FSMR 1166 3363 12 1 8 E 2 Fig 1 1 Front View...
Page 66: ......
Page 86: ......
Page 130: ...Menu Overview R S FSMR 1166 3363 12 3 42 E 3 Menu Overview another Keys MKR Key...
Page 141: ...R S FSMR Menu Overview 1166 3363 12 3 53 E 3 LOCAL Menu LOCAL...
Page 144: ......
Page 150: ......
Page 156: ......
Page 202: ......
Page 208: ......
Page 216: ......
Page 230: ......
Page 254: ......
Page 280: ......
Page 348: ......
Page 376: ...Configuration Setup R S FSMR 1166 3363 12 4 19 28 E 2...
Page 390: ......
Page 408: ......
Page 428: ......
Page 446: ......
Page 536: ......
Page 799: ......
Page 921: ......
Page 935: ......
Page 937: ...Contents Error Messages R S FSMR 1166 3363 12 I 9 2 E 1...