Network and Remote Operation
R&S
®
FSVA3000/ R&S
®
FSV3000
718
User Manual 1178.8520.02 ─ 01
Refer to
Chapter 12, "General Instrument Setup"
on page 561 to find out which func-
tions are affected.
At the same time you log on to the operating system, you are automatically logged on
to the network. As a prerequisite, the user name and the password must be identical
on the instrument and on the network.
13.6.3.1
How to Create Users
After the software for the network has been installed, the instrument issues an error
message the next time it is switched on because there is no user named "instrument"
(= default user ID for Windows automatic login) in the network. Thus, a matching user
must be created in the R&S
FSV/A and in the network, the password must be adapted
to the network password, and the automatic login mechanism must then be deactiva-
ted.
The network administrator is responsible for creating new users in the network.
1.
Select the "Windows" icon in the toolbar to access the operating system.
2. Select "Start > Settings > Accounts > Other users".
3. Select "Add someone else to this PC".
4. In the "Microsoft account" dialog box, enter the new user name and password.
5. Select "OK".
6. Select "Finish".
The new user is created.
13.6.3.2
How to Change the User Password
After the new user has been created on the instrument, the password must be adapted
to the network password.
1.
Select the "Windows" icon in the toolbar to access the operating system.
2. Press [Ctrl
+
Alt +
Delete], then select "Change a password".
3. Enter the user account name.
4. Enter the old password.
5. Enter the new password in the upper text line and repeat it in the following line.
6. Press [Enter].
How to Set Up a Network and Remote Control