Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
757
User Manual 1178.8520.02 ─ 01
If you set the channel spacing for a transmission channel, the R&S
FSV/A sets the
spacing of the lower transmission channels to the same value, but not the other way
round. The command works hierarchically: to set a distance between the 2nd and 3rd
and 3rd and 4th channel, you have to set the spacing between the 2nd and 3rd chan-
nel first.
Suffix:
<ch>
.
1..n
Tx channel number
Parameters:
<Spacing>
Range:
14 kHz to 2000 MHz
*RST:
20 kHz
Default unit: Hz
Manual operation:
See
[SENSe:]POWer:ACHannel:TXCHannel:COUNt
<Number>
This command defines the number of transmission channels.
The command works for measurements in the frequency domain.
Parameters:
<Number>
Range:
1 to 18
*RST:
1
Manual operation:
See
" Number of channels: Tx , Adj "
14.5.3.3
Defining Weighting Filters
The following commands define weighting filters for ACLR measurements.
[SENSe:]POWer:ACHannel:FILTer:ALPHa:ACHannel
........................................................ 757
[SENSe:]POWer:ACHannel:FILTer:ALPHa[:ALL]
............................................................... 758
[SENSe:]POWer:ACHannel:FILTer:ALPHa:ALTernate<ch>
................................................. 758
[SENSe:]POWer:ACHannel:FILTer:ALPHa:CHANnel<ch>
.................................................. 758
[SENSe:]POWer:ACHannel:FILTer[:STATe]:ACHannel
....................................................... 758
[SENSe:]POWer:ACHannel:FILTer[:STATe][:ALL]
.............................................................. 758
[SENSe:]POWer:ACHannel:FILTer[:STATe]:ALTernate<ch>
................................................ 759
[SENSe:]POWer:ACHannel:FILTer[:STATe]:CHANnel<ch>
................................................. 759
[SENSe:]POWer:ACHannel:FILTer:ALPHa:ACHannel
<Alpha>
This command defines the roll-off factor for the adjacent channel weighting filter.
Parameters:
<Alpha>
Roll-off factor
Range:
0 to 1
*RST:
0.22
Manual operation:
See
See
Configuring and Performing Measurements