Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
795
User Manual 1178.8520.02 ─ 01
14.5.6.4
Configuring a Sweep List
The following commands define a sweep list for SEM measurements.
The sweep list cannot be configured using remote commands during an on-going
sweep operation.
See also:
●
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:LIMit[:STATe]
.................................................................................. 795
[SENSe:]ESPectrum<sb>:RANGe<ri>:BANDwidth:RESolution
........................................... 796
[SENSe:]ESPectrum<sb>:RANGe<ri>:BANDwidth:VIDeo
.................................................. 796
[SENSe:]ESPectrum<sb>:RANGe<ri>:COUNt?
.................................................................797
[SENSe:]ESPectrum<sb>:RANGe<ri>:DELete
.................................................................. 797
[SENSe:]ESPectrum<sb>:RANGe<ri>:FILTer:TYPE
.......................................................... 797
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STARt
................................................................ 797
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STOP
.................................................................798
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:ATTenuation
..................................................798
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:ATTenuation:AUTO
........................................ 799
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:GAIN[:VALue]
................................................799
[SENSe:]ESPectrum<sb>:RANGe<ri>:INPut:GAIN:STATe
..................................................799
[SENSe:]ESPectrum<sb>:RANGe<ri>:INSert
....................................................................800
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:ABSolute:STARt
........................................ 800
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:ABSolute:STOP
........................................ 801
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STARt
........................................ 801
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STARt:ABS
................................. 802
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STARt:FUNCtion
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP
.........................................803
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP:ABS
................................. 803
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:RELative:STOP:FUNCtion
[SENSe:]ESPectrum<sb>:RANGe<ri>:LIMit<li>:STATe
...................................................... 805
[SENSe:]ESPectrum<sb>:RANGe<ri>:POINts:MINinum[:VALue]
........................................ 805
[SENSe:]ESPectrum<sb>:RANGe<ri>:MLCalc
..................................................................806
[SENSe:]ESPectrum<sb>:RANGe<ri>:RLEVel
.................................................................. 806
[SENSe:]ESPectrum<sb>:RANGe<ri>:SWEep:TIME
......................................................... 806
[SENSe:]ESPectrum<sb>:RANGe<ri>:SWEep:TIME:AUTO
............................................... 807
[SENSe:]ESPectrum<sb>:RANGe<ri>:TRANsducer
.......................................................... 807
.................................................................................. 808
[SENSe:]ESPectrum<sb>:HSPeed
<State>
This command turns high speed mode for SEM measurements on and off.
For more information including restrictions see
Chapter 7.6.4.3, "Fast SEM Measure-
Configuring and Performing Measurements