Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
817
User Manual 1178.8520.02 ─ 01
Example:
//Select the band category 1
ESP2:MSR:BCAT 1
//Set the base station class to medium range
ESP2:MSR:CLAS MED
//Set the maximum output power to 10 dBm.
ESP2:MSR:MPOW 10
//Set the frequency range of the base station to > 3 GHz
ESP2:MSR:BAND:HIGH
//Set the base station RF bandwidth to 20 MHz
ESP2:MSR:RFBW 20MHZ
//Calculate limits for MSR SEM
ESP2:MSR:APPL
Manual operation:
See
[SENSe:]ESPectrum<sb>:MSR:CLASs
<Class>
Defines the class of the base station according to its sending range.
Suffix:
<sb>
.
1..n
Sub block in a Multi-SEM measurement
Parameters:
<Class>
WIDE | MEDium | LOCal
WIDE
Wide Area
MEDium
Medium Range
LOCal
Local Area
*RST:
WIDE
Example:
//Select the band category 1
ESP2:MSR:BCAT 1
//Set the base station class to medium range
ESP2:MSR:CLAS MED
//Set the maximum output power to 10 dBm.
ESP2:MSR:MPOW 10
//Set the frequency range of the base station to > 3 GHz
ESP2:MSR:BAND:HIGH
//Set the base station RF bandwidth to 20 MHz
ESP2:MSR:RFBW 20MHZ
//Calculate limits for MSR SEM
ESP2:MSR:APPL
Manual operation:
See
Configuring and Performing Measurements