Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
923
User Manual 1178.8520.02 ─ 01
*RST:
AC
Example:
INP:COUP DC
Manual operation:
See
INPut<ip>:DPATh
<State>
Enables or disables the use of the direct path for frequencies close to 0
Hz.
Suffix:
<ip>
.
1 | 2
irrelevant
Parameters:
<State>
AUTO | OFF
AUTO | 1
(Default) the direct path is used automatically for frequencies
close to 0
Hz.
OFF | 0
The analog mixer path is always used.
Example:
INP:DPAT OFF
Manual operation:
See
INPut<ip>:FILTer:YIG[:STATe]
<State>
Suffix:
<ip>
.
1 | 2
irrelevant
Parameters:
<State>
ON | OFF | 0 | 1
*RST:
1 (0 for I/Q Analyzer, GSM, VSA, Pulse, Amplifier,
Transient Analysis, DOCSIS and MC Group Delay
measurements)
Example:
INP:FILT:YIG OFF
Deactivates the YIG-preselector.
Manual operation:
See
INPut<ip>:IMPedance
<Impedance>
This command selects the nominal input impedance of the RF input. In some applica-
tions, only 50
Ω
are supported.
Suffix:
<ip>
.
1 | 2
irrelevant
Setting Basic Measurement Parameters